Claude Skill

simulate-modelica-realtime

Run a compiled Modelica model as a live, real-time simulation server and interact with it over the System Modeler simulation TCP interface: start, pause, resume and stop it, set inputs and tunable parameters while it runs, read and stream values, or send raw protocol commands, on

LLM Mart · 0 points · 0 views 0 listing impressions 0 install-command copies
Download wolframresearch-system-modeler-ai-toolkit-simulate-modelica-realtime-7f6f400.zip · 10 KB

Install

skills CLI npx skills add https://github.com/WolframResearch/system-modeler-ai-toolkit/tree/main/simulate-modelica-realtime
Claude Code claude plugin marketplace add https://llmmart.ai/marketplace.json && claude plugin install wolframresearch-system-modeler-ai-toolkit@llmmart
Git git clone https://github.com/WolframResearch/system-modeler-ai-toolkit.git

The skills CLI installs just this skill, for any of its supported agents. Claude Code installs the whole wolframresearch/system-modeler-ai-toolkit collection as a plugin from our marketplace. Git is the plain clone.

Skill manifest

Talk to a simulation executable

Every simulation System Modeler builds is an executable plus a .sim settings file, and every running simulation has a built-in TCP server. A client can start, pause, resume and stop the run, set top-level inputs at any time, set tunable parameters while the solver runs, read any variable, and subscribe to variables that are then streamed while it runs. This skill does that with the stdlib-only client <scripts-dir>/wsmsim.py and its command line <scripts-dir>/wsm_realtime.py. Resolve <scripts-dir> as in Appendix → Locating the launcher, and follow its shell and Python rules per OS.

1. Get a simulation to talk to

Either of these works:

  • Launch an executable. Build the model with the simulate-modelica skill, and keep its _wsm_simulate_temp/ (the launcher prints its path as temp dir :): it holds <Model>_<id>.exe and its .sim. Give that directory as <target> with --model ModelName (or the executable path) below; the CLI starts it in server mode, paced to the wall clock, on a free port.
  • Attach to a running simulation. A simulation started in Simulation Center, or by hand with <Model>_<id>.exe -f <Model>_<id>.sim -server 127.0.0.1:7000, is already listening; the simulation log shows the address (Server listening on 127.0.0.1:<port>). Pass --attach host:port instead of a target. An attached client never stops the simulation when it disconnects, so several clients can share one run.

Only top-level input variables can be changed while the solver runs, and only tunable parameters after the start. If the model exposes nothing to steer, add input Real u(start = ...) variables (or a wrapper model) for the quantities the user wants to drive, and make the display quantities top-level outputs; validate with validate-modelica.

2. Inspect the interface as the server sees it

python3 "<scripts-dir>/wsm_realtime.py" info <target> --model ModelName

Prints inputs and their start values, outputs, tunable parameters and states. Use these exact names below; nested names use dots (load.p), array elements [k]. Every streamed sample already carries the simulation time, so do not subscribe to time.

3. Run a scripted scenario

python3 "<scripts-dir>/wsm_realtime.py" run <target> --model ModelName \
  --watch flow,angle,status --duration 30 --scale 2 \
  --set 5:Pset=4500 --set 12:breakerClosed=false --param 0:sensWarn=3 --param 8:T=1 \
  --csv run.csv
  • --scale N: N simulated seconds per wall second; --fast runs without pacing and takes no timed changes.
  • --set T:name=value: input change T simulated seconds into the run. --param T:name=value: parameter change; T=0 is applied before the start, later times need a tunable parameter. --duration and T count from the start or, with --attach to a simulation that is already running, from the moment of attaching; a simulation that has not started yet is started.
  • Values stream once per output interval (the model's Interval, or --interval 0.01), plus one sample at each event instant carrying the values from just before the event. A change is sent at the first sample at or after its time and takes effect from the next solver step, so up to one output interval later; model the change in Modelica when its exact time matters.
  • --step 0.01 --method explicit-euler: fixed-step integration (also rk4, heuns-method); the default is the model's own solver settings.
  • One printed row per --print-every simulated seconds; --csv records every sample received.
  • The run ends with the packet count and the gaps longer than the output interval, and exits non-zero if simulated time stopped short of --duration. The server sends the newest sample whenever it can, so a gap means samples were skipped (common with --fast); the stream is not a complete result — simulate-modelica gives that.

4. Send protocol commands directly

python3 "<scripts-dir>/wsm_realtime.py" cmd --attach 127.0.0.1:63597 \
  -c 'getVariableNames()' -c 'setInputValues({"u", 2.3})' -c 'getVariableValues({"y"})'

Each reply is printed as the server sends it ({"u", "y", "k"}, {true}, {4.6}); a refused command prints the server's error text. Without -c the commands are read one per line from standard input. Commands:

Command Effect
getModelName(), getTime(), getStopTime(), getSimulationState() model name; current and stop time; 1 not started, 2 running, 3 suspended
getVariableNames(), getInputVariableNames(), getOutputVariableNames(), getParameterNames(), getTunableParameterNames(), getStateVariableNames() name lists
getVariableValues({"a", "b"}) current values
setInputValues({"u", 2.3, "v", 0}) inputs, used from the next step
setParameterValues({"T", 1.0}) before the start: a parameter from getParameterNames(); after: a tunable one
setSubscription({"a", "b"}) returns a subscription id; values then stream on a data session
startSimulation(), suspendSimulation(), continueSimulation(), stopSimulation() run control

Boolean values may be written true/false or 1/0. To run again from the start, use the Restart button of the live view (section 5) or restart() in Python (section 6), not restartSimulation(), which ends the simulation process. Evaluated and structural parameters are in neither parameter list; changing them needs a rebuild.

5. Live view with controls

python3 "<scripts-dir>/wsm_realtime.py" plot <target> --model ModelName \
  --watch flow,angle --sliders Pset:0:7500,V:0.85:1.1 --toggles breakerClosed

Live curves with sliders and check boxes writing the inputs, and a Pause/Run button; a launched simulation also gets a Restart button. Needs a display.

6. Custom logic from Python

import sys; sys.path.insert(0, "<scripts-dir>")
from wsmsim import WsmSimulation, find_simulation
exe, sim = find_simulation("<build-dir>", "ModelName")
with WsmSimulation.launch(exe, sim, scale=1.0) as s:          # or WsmSimulation.attach(host, port)
    sub = s.subscribe(["flow", "angle"])
    s.set_parameters(sensWarn=3.0)                              # before start
    s.start()
    for t, row in s.stream(sub, seconds=10):                    # (sim_time, {name: value}) per sample
        if row["angle"] > 30:
            s.set_inputs(Pset=3000)                             # Booleans may be True/False here
    s.set_parameters(T=1.0)                                     # tunable parameter, mid-run
    s.suspend(); s.resume(); s.get_values(["flow", "P"]); s.stop()

launch writes an interactive copy of the .sim (long stop time, the model's output interval, real-time pacing, no result file), starts the executable on a free port and removes the copy when it exits; attach connects to a running server and leaves it running on close. s.latest(sub) gives the newest sample without consuming the stream; s.send_inputs([...]) sends all inputs as one binary packet in s.inputs order, for high-rate feeds (paced runs only); s.restart() relaunches a launched simulation from the start, keeping its subscriptions and the values set through s; s.scs.command_raw(text) sends any protocol command.

Behaviour to rely on

  • The server does nothing until startSimulation(); connecting does not start the run.
  • Without real-time pacing the executable runs its whole horizon as fast as it can. The CLI and launch enable pacing unless told otherwise; a simulation started elsewhere keeps its own settings.
  • Suspending stops the run at the end of the current step and holds the time there.
  • When a simulation reaches its stop time the process exits and closes every connection.

Protocol, for clients in other languages

Documented in the System Modeler User Guide, "Communication with Simulation via TCP" (reference.wolfram.com/system-modeler/UserGuide/CommunicationwithSimulationviaTCP.html). In short: every packet is an 8-byte little-endian header — version (1), type, one byte with the subscription id on data packets, one byte with the simulation state, and a 4-byte payload length — followed by the payload. A control session opens with a HELLO_SCS packet (type 1) and gets its session id back ({1}); commands are text in CMD packets (type 3), answered by CMD_REPLY (4) or CMD_ERROR (5). A data session opens with HELLO_SDS (type 2) carrying that session id in braces, and then receives type 6 packets: the simulation time followed by the subscribed values, all doubles. A type 8 packet on the data session sets all inputs at once, as doubles. Send Boolean values in commands as 1/0. wsmsim.py is a complete implementation.

7. Report and clean up

Report the scenario, what changed at which simulated time, the key values, and the packet count and gaps. A launched executable leaves <Model>_<id>_server.log next to itself; remove the whole _wsm_simulate_temp/ when the user is done with the executable — commands per OS: Appendix → Temporary directories.

Edge cases

  • Unknown variable (subscribe, read) or Not an input variable (set): check the names with info.
  • Not a valid parameter to set: after the start the parameter is not tunable; before it, the parameter is evaluated or structural. Set it at T=0, or change the model and rebuild.
  • Executable exits at once: read <Model>_<id>_server.log in the build directory; a model that fails initialization or a wrong .sim path shows there.
  • Simulated time stops advancing while samples keep arriving (run reports that it stopped short of --duration): the model is chattering on an event, e.g. a condition that switches the integrator of a saturated controller on and off. The server log shows Event burst count reached warning threshold and the expression causing it; reformulate that part of the model and rebuild.
  • Connection closed or refused on an attached run: the simulation reached its stop time and exited; a simulation started elsewhere keeps the stop time from its own settings.
  • Web or other clients: the server speaks TCP only; put a small bridge (WebSocket or server-sent events) in front of wsmsim.py for browsers.

Appendix: shared conventions for the Modelica skills

Shared by every Modelica skill that drives WSMKernelX through the bundled launcher; inlined here at release time. For the CLI/option reference, environment variables (WSM_HOME, WSM_VSDEVCMD), install discovery, and the analysis scripts, see ../scripts/README.md.

These are conventions, not a workflow. Knowing how to call the tools is not the same as knowing which to call, in what order, and how to tell a good answer from a plausible one — that lives in the skills, one per job. Invoke the one that owns the step you are on, including when it is not the one you started from: a job that begins in one skill routinely runs into something another one owns, and the whole toolkit is available the entire time.

What you run into Skill
About to write or restructure a model or library — including one you decided to build yourself modelica-model-architecture first
A .mo you just wrote or edited; a structural error validate-modelica
You need results simulate-modelica (simulate-and-plot-modelica to plot them too)
A run that must go in real time, take input changes while it runs, or be driven from another program simulate-modelica-realtime
It validates but will not build; it runs far too slowly; it gives an answer you cannot account for; you need its states, equations or blocks diagnose-modelica
The launcher reports a compiler failure — an internal error, generated code that does not compile, a simulator internal error or a kernel crash minimize-modelica-bug
A Modelica language or MSL question you would otherwise answer from memory search-modelica-docs
Sweeps, limit checks, calibration, custom result analysis wolfram-language-modelica
No icons, or no diagram layout annotate-modelica-graphics
Plots that should live in the model and reopen with it annotate-modelica-plots
Interactive sliders in Simulation Center's Explore view annotate-control-panel
3D MultiBody animation annotate-modelica-animation
A hydraulic circuit create-hydraulic-model

Locating the launcher

<scripts-dir> (used throughout the skills) is the shared scripts/ folder. Some installs symlink the skill directories without it, so resolve it in this order and use the first that exists:

  1. $WSM_SKILLS_SCRIPTS (bash) or $env:WSM_SKILLS_SCRIPTS (PowerShell), if set.
  2. ../scripts relative to the skill directory — in a normal install ../scripts/wsm_run.py already exists, so use that path directly; do not run a shell probe to "resolve" it.
  3. The folder you cloned or unzipped the skills from, e.g. .../system-modeler-ai-toolkit/scripts.
  4. Last resort, search the home directory:
    • PowerShell: Get-ChildItem $HOME -Recurse -Filter wsm_run.py -ErrorAction SilentlyContinue | Select-Object -First 1
    • bash/zsh: find ~ -name wsm_run.py -path '*scripts*' 2>/dev/null | head -1

If only #4 finds it, the install is missing the scripts/ link — tell the user to run install.sh (or install.ps1) from the repo, which links scripts/ too.

Shell and Python

On Windows, use PowerShell. The Git-Bash/cygwin layer may be broken (even ls/find can be absent, giving a misleading "exit 127 / command not found"). Run wsm_run.py with python (not python3); those calls are single-line and shell-agnostic. For cleanup use Remove-Item -Recurse -Force, not rm -rf. On macOS/Linux any POSIX shell is fine and python3 is the usual name.

For your own analysis, borrow the scripts' interpreter. Whatever python3 you get is unlikely to have numpy or scipy, and installing into it is both rude and often blocked. The analysis scripts run under a managed virtualenv with numpy, scipy, matplotlib and DyMat; python3 <scripts-dir>/bootstrap_env.py makes sure they are installed there and prints its interpreter path. Use that interpreter for ad-hoc post-processing rather than discovering package by package what the system one lacks.

Line endings in .mo files

Modelica models are written on Windows, macOS and Linux alike, so a .mo file may use CRLF or LF. Neither is the "right" one. Match whatever the file already has, and never leave a file with a mix of both — a mixed file shows up as a whole-file diff the moment anything rewrites it, burying the real change.

When you edit a .mo yourself with the Write/Edit tools (rather than through one of the annotator scripts), those tools write back exactly the text you give them, so an edit in the other style silently mixes the file. Check before, and check again after:

python3 "<scripts-dir>/mo_edit.py" --eol "<Model.mo>"

It prints LF, CRLF, MIXED (crlf=N lf=M) or NONE, and exits non-zero on MIXED. If an edit did change the endings, put them back — this rewrites the whole file to one ending, so it also repairs a mixed one:

python3 "<scripts-dir>/mo_edit.py" --set-eol auto "<Model.mo>"   # or: lf, or crlf

A mixed file follows its library, not itself. If the file you are editing is mixed while the rest of the library is consistent, do not settle it on whichever ending dominates inside that file — the mixing is damage, so the file is not evidence about itself, and its majority leaves you with the one odd file out. Use the library's ending. auto does this for you, and reports which rule it applied.

Creating a new .mo: same rule — match the sibling .mo files in the same directory or library (--eol accepts several paths at once), so one library does not end up half CRLF and half LF. Use LF only when there is nothing to match.

The annotator scripts' --write paths already preserve the file's endings and warn about a mixed input, so no manual step is needed around those.

Let the launcher own .mos/.bat and paths

Do not hand-write .mos scripts, .bat files, or hardcode install/compiler paths. The bundled scripts/wsm_run.py handles every OS difference — it finds the System Modeler install and kernel binary (macOS / Windows / Linux), finds and loads the right MSL files, generates the .mos, and runs the kernel with a working compiler environment per platform (system clang/gcc on macOS/Linux; the Visual Studio dev environment via VsDevCmd.bat on Windows). See ../scripts/README.md for WSM_HOME, the Windows compiler prerequisites, and the full option table.

When the install or compiler isn't found

The launcher searches each OS's standard install locations. If it prints ERROR: Could not locate a Wolfram System Modeler installation, the install is in a non-standard place — ask the user for it and re-run with --wsm-home "<path>" (or have them set WSM_HOME).

Building and simulating also need a C++ toolchain:

  • Windows: Visual Studio Build Tools. The launcher locates VsDevCmd.bat itself; if it reports the compiler environment is missing, pass --vsdevcmd "<path-to-VsDevCmd.bat>" (or set WSM_VSDEVCMD) and make sure Build Tools are installed.
  • macOS: the Xcode command-line tools (xcode-select --install).
  • Linux: gcc/g++.

Run python3 "<scripts-dir>/wsm_run.py" --mode info to see what the launcher discovered.

Checking the setup

When the user asks whether the machine is ready for these skills, run python3 <scripts-dir>/wsm_run.py --mode info and report what it prints: the System Modeler installation it found and, on Windows, the compiler environment. If InstallationGuide.md sits next to the scripts/ folder, as it does when the skills are installed as a plugin, it lists what each skill needs: follow its Steps 2, 4 and 5, and do not run the installer.

Temporary directories

The launcher works in a _wsm_<mode>_temp/ directory (_wsm_validate_temp/, _wsm_simulate_temp/, _wsm_diagnose_temp/) and leaves its outputs there. It sits next to a single .mo file, or next to the top folder of a directory-form library, never inside the library. The launcher prints its path as temp dir :; <temp-dir> in the skills means that path. Tell the user, e.g.: "Working in temporary directory _wsm_<mode>_temp/. This will be deleted afterwards." Pass --tempdir to reuse one directory across models in a session.

Clean up by removing the whole directory — use the user's shell:

rm -rf "<temp-dir>"          # macOS / Linux
# PowerShell: Remove-Item -Recurse -Force "<temp-dir>"

Picking the model name

  • The user may provide a path to a .mo file, or you may already be working with one in context.

  • Extract the model name: the identifier after model on the first non-comment line, e.g. model FooBar → FooBar. The filename does not always match the model name — parse the actual model/package declaration.

  • For packages or nested models, use the top-level model name.

  • Pick an instantiable model, not a package, for any kernel call. A package cannot be validated or simulated ("Invalid instantiation … is a package") — use a nested model's full dotted name, e.g. Package.Model.

  • Pass an absolute path to --model (relative paths break as the working directory shifts between calls).

  • A class that is already in a loaded library needs no --model at all — give just the full dotted --name and the launcher takes it from MSL (or from a --load-library library). Use this for MSL examples rather than writing a wrapper model that extends one:

    python3 "<scripts-dir>/wsm_run.py" --mode diagnose \
      --name Modelica.Mechanics.MultiBody.Examples.Loops.EngineV6
    

    The temp dir then goes in the current directory. --model is still required for a class in the user's own file.

Directory-form (multi-file) libraries

A directory-form library stores one class per file with a package.mo at each level. You cannot validate such a class by handing the launcher only its own .mo file — the class's within Lib; clause needs the whole package loaded, and loading the single file alone fails with Internal error: ... expandLibNode: Unknown library: Lib. Instead point --model at the library folder (or its top package.mo, or any class file inside it) and pass the full dotted class name via --name:

python3 "<scripts-dir>/wsm_run.py" --mode validate \
  --model "/abs/path/InvertedPendulum" \
  --name InvertedPendulum.Controller

The launcher resolves any of those forms up to the library's root package.mo and loads the entire package (following package.order) before instantiating --name. It prints a NOTE: telling you which package.mo it loaded. Do not try to work around the unknown-library error by --load-ing individual files.

Reading the JSON output

The kernel writes <mode>.out.json into the temp dir. It is a JSON array — take the first element, then read:

  • status.flatten: "Pass" / "Fail" (the primary result for validate).
  • status.build: "Pass" / "Fail" — C++ compilation/linking (simulate).
  • status.result: simulation result status (simulate).
  • messages.errors / messages.warnings / messages.notifications: arrays (empty if none).
  • flat_model (validate) / simulation.resultFile (simulate): the flattened class / path to the .mat.

See ../scripts/README.md (wsm_run.py section) for the full field reference.

Checking graphic annotations

A plain run does not evaluate the graphic annotations: Icon, Diagram and Placement are carried along untouched, so an error inside one cannot fail the run. Add --graphics to have them evaluated together with the model:

python3 "<scripts-dir>/wsm_run.py" --mode validate --graphics \
  --model "<Model.mo>" --name "<Package>.<ModelName>" --timeout 90

Errors then arrive through the usual status.flatten and messages.errors: a variable or component path that does not resolve, a misspelled shape (Rectangel) or field (extend), an array subscript out of bounds. This mode needs no C++ compiler, so it is the gate to run after editing annotations.

The compiling modes (--mode simulate, --mode diagnose) additionally generate the model's diagram view, which evaluates the animated (DynamicSelect) expressions themselves. The launcher prints a graphics : line naming the generated view; if it was not generated it says so and exits non-zero, meaning an animated field could not be evaluated. It also exits non-zero, listing them, when an animated value falls back to its static value — typically an expression using a function the diagram does not support. Nothing else reports either.

Evaluating the annotations is extra work for the frontend, so pass --graphics when the annotations are what you changed or are checking, not by default.

Not every System Modeler version supports --graphics. On one that does not, the launcher drops it with a NOTE: and runs without it, so the graphic annotations are not checked; say so rather than reporting them as valid.

MSL 4.x dialect

This toolchain ships MSL 4.x. When authoring models, use the 4.x names — the 3.2 names flatten with confusing "not found" errors:

  • units: Modelica.Units.SI.* (not Modelica.SIunits.*)
  • source frequency parameter: f (not freqHz), e.g. SineVoltage(V=.., f=..)
  • declare the dependency with the exact MSL version, e.g. annotation(uses(Modelica(version="4.1.0")))

Run python3 "<scripts-dir>/wsm_run.py" --mode info to get the exact MSL version. wsm_run.py also warns on stderr if it spots a 3.2 name in the model.

When a flatten fails with Element not found ... in Modelica..., the MSL component path is wrong (a misremembered name, not a missing install). Resolve the correct path with the search-modelica-docs skill — e.g. sine is Modelica.Blocks.Sources.Sine (not Math.Sine), difference is Math.Feedback (not Math.Subtract), and saturation is Nonlinear.Limiter (not Nonlinear.Saturation). Do not grep or walk the System Modeler install tree to hunt for the class.

Using non-MSL libraries (Hydraulic, and other installed libraries)

MSL is automatic (--msl). For any other library a model uses — Hydraulic, or anything the user installed from the Library Store — the launcher can find it for you. Two steps, no guessing at paths:

  1. See what is installed (bundled with System Modeler, user-installed archives, and any custom folders configured in Model Center):

    python3 "<scripts-dir>/wsm_run.py" --mode libraries
    # add --json for a machine-readable array; each row has name/version/source/package
    

    To get just one library's package path (e.g. for a manual --load): --mode libraries --library Hydraulic (add --library-version 2.1 to pin a version).

  2. Load it into a build by name — add --load-library <Name> to a validate / simulate / diagnose run (repeatable; pin a version with Name==Ver):

    python3 "<scripts-dir>/wsm_run.py" --mode validate \
      --model "<path>/M.mo" --name M --load-library Hydraulic
    

    The launcher resolves the library (bundled → user-installed → Model-Center custom path, newest version wins) and loadFiles it before the model. A library usually pulls in MSL, so keep MSL on (auto, or --msl yes). Override a lookup with $WSM_LIBRARY_<NAME> (e.g. WSM_LIBRARY_HYDRAULIC=/path/to/package.moe), or fall back to an explicit --load <path-to-package.mo|.moe>.

Files (system-modeler-ai-toolkit)
  • SKILL.md 26.4 KB
    ---
    name: simulate-modelica-realtime
    description: "Run a compiled Modelica model as a live, real-time simulation server and interact with it over the System Modeler simulation TCP interface: start, pause, resume and stop it, set inputs and tunable parameters while it runs, read and stream values, or send raw protocol commands, on an executable it launches or one already running in Simulation Center. Use it whenever a simulation must run in real time or as a server, take input or parameter changes mid-run, be driven from Python or another program, or feed an operator, hardware-in-the-loop or live-dashboard demo. Triggers on phrases like 'run in real time', 'simulate in server mode', 'connect to the running simulation', 'change the input while it runs', 'stream simulation values', 'hardware in the loop', 'simulation server', 'TCP interface of the simulation'. For one-shot simulations use simulate-modelica; for live interaction from Wolfram Language use wolfram-language-modelica."
    ---
    
    # Talk to a simulation executable
    
    Every simulation System Modeler builds is an executable plus a `.sim` settings file, and every
    running simulation has a built-in TCP server. A client can start, pause, resume and stop the run,
    set top-level inputs at any time, set tunable parameters while the solver runs, read any variable,
    and subscribe to variables that are then streamed while it runs. This skill does that with the
    stdlib-only client `<scripts-dir>/wsmsim.py` and its command line `<scripts-dir>/wsm_realtime.py`.
    Resolve `<scripts-dir>` as in [Appendix → Locating the launcher](#locating-the-launcher),
    and follow its shell and Python rules per OS.
    
    ## 1. Get a simulation to talk to
    
    Either of these works:
    
    - **Launch an executable.** Build the model with the simulate-modelica skill, and keep
      its `_wsm_simulate_temp/` (the launcher prints its path as `temp dir :`): it holds `<Model>_<id>.exe` and its `.sim`. Give that
      directory as `<target>` with `--model ModelName` (or the executable path) below; the CLI starts
      it in server mode, paced to the wall clock, on a free port.
    - **Attach to a running simulation.** A simulation started in Simulation Center, or by hand with
      `<Model>_<id>.exe -f <Model>_<id>.sim -server 127.0.0.1:7000`, is already listening; the
      simulation log shows the address (`Server listening on 127.0.0.1:<port>`). Pass
      `--attach host:port` instead of a target. An attached client never stops the simulation when it
      disconnects, so several clients can share one run.
    
    Only top-level `input` variables can be changed while the solver runs, and only tunable
    parameters after the start. If the model exposes nothing to steer, add `input Real u(start = ...)`
    variables (or a wrapper model) for the quantities the user wants to drive, and make the display
    quantities top-level `output`s; validate with validate-modelica.
    
    ## 2. Inspect the interface as the server sees it
    
    ```bash
    python3 "<scripts-dir>/wsm_realtime.py" info <target> --model ModelName
    ```
    
    Prints inputs and their start values, outputs, tunable parameters and states. Use these exact
    names below; nested names use dots (`load.p`), array elements `[k]`. Every streamed sample already
    carries the simulation time, so do not subscribe to `time`.
    
    ## 3. Run a scripted scenario
    
    ```bash
    python3 "<scripts-dir>/wsm_realtime.py" run <target> --model ModelName \
      --watch flow,angle,status --duration 30 --scale 2 \
      --set 5:Pset=4500 --set 12:breakerClosed=false --param 0:sensWarn=3 --param 8:T=1 \
      --csv run.csv
    ```
    
    - `--scale N`: N simulated seconds per wall second; `--fast` runs without pacing and takes no
      timed changes.
    - `--set T:name=value`: input change T simulated seconds into the run. `--param T:name=value`:
      parameter change; T=0 is applied before the start, later times need a tunable parameter.
      `--duration` and T count from the start or, with `--attach` to a simulation that is already
      running, from the moment of attaching; a simulation that has not started yet is started.
    - Values stream once per **output interval** (the model's `Interval`, or `--interval 0.01`), plus
      one sample at each event instant carrying the values from just before the event. A change is
      sent at the first sample at or after its time and takes effect from the next solver step, so
      up to one output interval later; model the change in Modelica when its exact time matters.
    - `--step 0.01 --method explicit-euler`: fixed-step integration (also `rk4`, `heuns-method`);
      the default is the model's own solver settings.
    - One printed row per `--print-every` simulated seconds; `--csv` records every sample received.
    - The run ends with the packet count and the gaps longer than the output interval, and exits
      non-zero if simulated time stopped short of `--duration`. The server
      sends the newest sample whenever it can, so a gap means samples were skipped (common with
      `--fast`); the stream is not a complete result — simulate-modelica gives that.
    
    ## 4. Send protocol commands directly
    
    ```bash
    python3 "<scripts-dir>/wsm_realtime.py" cmd --attach 127.0.0.1:63597 \
      -c 'getVariableNames()' -c 'setInputValues({"u", 2.3})' -c 'getVariableValues({"y"})'
    ```
    
    Each reply is printed as the server sends it (`{"u", "y", "k"}`, `{true}`, `{4.6}`); a refused
    command prints the server's error text. Without `-c` the commands are read one per line from
    standard input. Commands:
    
    | Command | Effect |
    |---|---|
    | `getModelName()`, `getTime()`, `getStopTime()`, `getSimulationState()` | model name; current and stop time; 1 not started, 2 running, 3 suspended |
    | `getVariableNames()`, `getInputVariableNames()`, `getOutputVariableNames()`, `getParameterNames()`, `getTunableParameterNames()`, `getStateVariableNames()` | name lists |
    | `getVariableValues({"a", "b"})` | current values |
    | `setInputValues({"u", 2.3, "v", 0})` | inputs, used from the next step |
    | `setParameterValues({"T", 1.0})` | before the start: a parameter from `getParameterNames()`; after: a tunable one |
    | `setSubscription({"a", "b"})` | returns a subscription id; values then stream on a data session |
    | `startSimulation()`, `suspendSimulation()`, `continueSimulation()`, `stopSimulation()` | run control |
    
    Boolean values may be written `true`/`false` or `1`/`0`. To run again from the start, use the
    Restart button of the live view (section 5) or `restart()` in Python (section 6), not
    `restartSimulation()`, which ends the simulation process. Evaluated and structural parameters are
    in neither parameter list; changing them needs a rebuild.
    
    ## 5. Live view with controls
    
    ```bash
    python3 "<scripts-dir>/wsm_realtime.py" plot <target> --model ModelName \
      --watch flow,angle --sliders Pset:0:7500,V:0.85:1.1 --toggles breakerClosed
    ```
    
    Live curves with sliders and check boxes writing the inputs, and a Pause/Run button; a launched
    simulation also gets a Restart button. Needs a display.
    
    ## 6. Custom logic from Python
    
    ```python
    import sys; sys.path.insert(0, "<scripts-dir>")
    from wsmsim import WsmSimulation, find_simulation
    exe, sim = find_simulation("<build-dir>", "ModelName")
    with WsmSimulation.launch(exe, sim, scale=1.0) as s:          # or WsmSimulation.attach(host, port)
        sub = s.subscribe(["flow", "angle"])
        s.set_parameters(sensWarn=3.0)                              # before start
        s.start()
        for t, row in s.stream(sub, seconds=10):                    # (sim_time, {name: value}) per sample
            if row["angle"] > 30:
                s.set_inputs(Pset=3000)                             # Booleans may be True/False here
        s.set_parameters(T=1.0)                                     # tunable parameter, mid-run
        s.suspend(); s.resume(); s.get_values(["flow", "P"]); s.stop()
    ```
    
    `launch` writes an interactive copy of the `.sim` (long stop time, the model's output interval,
    real-time pacing, no result file), starts the executable on a free port and removes the copy when
    it exits; `attach` connects to a running server and leaves it running on close. `s.latest(sub)`
    gives the newest sample without consuming the stream; `s.send_inputs([...])` sends all inputs as
    one binary packet in `s.inputs` order, for high-rate feeds (paced runs only); `s.restart()`
    relaunches a launched simulation from the start, keeping its subscriptions and the values set
    through `s`; `s.scs.command_raw(text)` sends any protocol command.
    
    ## Behaviour to rely on
    
    - The server does nothing until `startSimulation()`; connecting does not start the run.
    - Without real-time pacing the executable runs its whole horizon as fast as it can. The CLI and
      `launch` enable pacing unless told otherwise; a simulation started elsewhere keeps its own
      settings.
    - Suspending stops the run at the end of the current step and holds the time there.
    - When a simulation reaches its stop time the process exits and closes every connection.
    
    ## Protocol, for clients in other languages
    
    Documented in the System Modeler User Guide, "Communication with Simulation via TCP"
    (reference.wolfram.com/system-modeler/UserGuide/CommunicationwithSimulationviaTCP.html). In
    short: every packet is an 8-byte little-endian header — `version` (1), `type`, one byte with the
    subscription id on data packets, one byte with the simulation state, and a 4-byte payload length —
    followed by the payload. A control session opens with a `HELLO_SCS` packet (type 1) and gets its
    session id back (`{1}`); commands are text in `CMD` packets (type 3), answered by `CMD_REPLY` (4)
    or `CMD_ERROR` (5). A data session opens with `HELLO_SDS` (type 2) carrying that session id in
    braces, and then receives type 6 packets: the simulation time followed by the subscribed values,
    all doubles. A type 8 packet on the data session sets all inputs at once, as doubles. Send Boolean
    values in commands as `1`/`0`. `wsmsim.py` is a complete implementation.
    
    ## 7. Report and clean up
    
    Report the scenario, what changed at which simulated time, the key values, and the packet count
    and gaps. A launched executable leaves `<Model>_<id>_server.log` next to itself; remove the
    whole `_wsm_simulate_temp/` when the user is done with the executable — commands per OS:
    [Appendix → Temporary directories](#temporary-directories).
    
    ## Edge cases
    
    - **`Unknown variable`** (subscribe, read) or **`Not an input variable`** (set): check the names
      with `info`.
    - **`Not a valid parameter to set`**: after the start the parameter is not tunable; before it, the
      parameter is evaluated or structural. Set it at T=0, or change the model and rebuild.
    - **Executable exits at once**: read `<Model>_<id>_server.log` in the build directory; a model
      that fails initialization or a wrong `.sim` path shows there.
    - **Simulated time stops advancing while samples keep arriving** (`run` reports that it stopped
      short of `--duration`): the model is chattering on an event, e.g. a condition that switches the integrator of a saturated controller on and off.
      The server log shows `Event burst count reached warning threshold` and the expression causing
      it; reformulate that part of the model and rebuild.
    - **Connection closed or refused on an attached run**: the simulation reached its stop time and
      exited; a simulation started elsewhere keeps the stop time from its own settings.
    - **Web or other clients**: the server speaks TCP only; put a small bridge (WebSocket or
      server-sent events) in front of `wsmsim.py` for browsers.
    
    ---
    
    ## Appendix: shared conventions for the Modelica skills
    
    > *Shared by every Modelica skill that drives WSMKernelX through the
    > bundled launcher; inlined here at release time. For the CLI/option
    > reference, environment variables (`WSM_HOME`, `WSM_VSDEVCMD`),
    > install discovery, and the analysis scripts, see
    > [`../scripts/README.md`](../scripts/README.md).*
    
    **These are conventions, not a workflow.** Knowing how to call the tools is not
    the same as knowing which to call, in what order, and how to tell a good answer
    from a plausible one — that lives in the skills, one per job. Invoke the one that
    owns the step you are on, **including when it is not the one you started from**:
    a job that begins in one skill routinely runs into something another one owns,
    and the whole toolkit is available the entire time.
    
    | What you run into | Skill |
    |---|---|
    | About to write or restructure a model or library — including one you decided to build yourself | `modelica-model-architecture` **first** |
    | A `.mo` you just wrote or edited; a structural error | `validate-modelica` |
    | You need results | `simulate-modelica` (`simulate-and-plot-modelica` to plot them too) |
    | A run that must go in real time, take input changes while it runs, or be driven from another program | `simulate-modelica-realtime` |
    | It validates but will not build; it runs far too slowly; it gives an answer you cannot account for; you need its states, equations or blocks | `diagnose-modelica` |
    | The launcher reports a `compiler failure` — an internal error, generated code that does not compile, a simulator internal error or a kernel crash | `minimize-modelica-bug` |
    | A Modelica language or MSL question you would otherwise answer from memory | `search-modelica-docs` |
    | Sweeps, limit checks, calibration, custom result analysis | `wolfram-language-modelica` |
    | No icons, or no diagram layout | `annotate-modelica-graphics` |
    | Plots that should live in the model and reopen with it | `annotate-modelica-plots` |
    | Interactive sliders in Simulation Center's Explore view | `annotate-control-panel` |
    | 3D MultiBody animation | `annotate-modelica-animation` |
    | A hydraulic circuit | `create-hydraulic-model` |
    
    ### Locating the launcher
    
    `<scripts-dir>` (used throughout the skills) is the shared `scripts/` folder.
    Some installs symlink the skill directories without it, so resolve it in this
    order and use the first that exists:
    
    1. `$WSM_SKILLS_SCRIPTS` (bash) or `$env:WSM_SKILLS_SCRIPTS` (PowerShell), if set.
    2. `../scripts` relative to the skill directory — in a normal install
       `../scripts/wsm_run.py` already exists, so use that path directly; **do not run
       a shell probe to "resolve" it.**
    3. The folder you cloned or unzipped the skills from, e.g.
       `.../system-modeler-ai-toolkit/scripts`.
    4. Last resort, search the home directory:
       - PowerShell: `Get-ChildItem $HOME -Recurse -Filter wsm_run.py -ErrorAction SilentlyContinue | Select-Object -First 1`
       - bash/zsh: `find ~ -name wsm_run.py -path '*scripts*' 2>/dev/null | head -1`
    
    If only #4 finds it, the install is missing the `scripts/` link — tell the user
    to run `install.sh` (or `install.ps1`) from the repo, which links `scripts/` too.
    
    ### Shell and Python
    
    **On Windows, use PowerShell.** The Git-Bash/cygwin layer may be broken (even
    `ls`/`find` can be absent, giving a misleading "exit 127 / command not found").
    Run `wsm_run.py` with `python` (not `python3`); those calls are single-line and
    shell-agnostic. For cleanup use `Remove-Item -Recurse -Force`, not `rm -rf`.
    On macOS/Linux any POSIX shell is fine and `python3` is the usual name.
    
    **For your own analysis, borrow the scripts' interpreter.** Whatever `python3`
    you get is unlikely to have numpy or scipy, and installing into it is both rude
    and often blocked. The analysis scripts run under a managed virtualenv with
    numpy, scipy, matplotlib and DyMat; `python3 <scripts-dir>/bootstrap_env.py`
    makes sure they are installed there and prints its interpreter path. Use that
    interpreter for ad-hoc post-processing rather than discovering package by
    package what the system one lacks.
    
    ### Line endings in .mo files
    
    Modelica models are written on Windows, macOS and Linux alike, so a `.mo` file
    may use CRLF or LF. **Neither is the "right" one.** Match whatever the file
    already has, and never leave a file with a mix of both — a mixed file shows up
    as a whole-file diff the moment anything rewrites it, burying the real change.
    
    When you edit a `.mo` yourself with the Write/Edit tools (rather than through one
    of the annotator scripts), those tools write back exactly the text you give them,
    so an edit in the other style silently mixes the file. Check before, and check
    again after:
    
    ```bash
    python3 "<scripts-dir>/mo_edit.py" --eol "<Model.mo>"
    ```
    
    It prints `LF`, `CRLF`, `MIXED (crlf=N lf=M)` or `NONE`, and exits non-zero on
    `MIXED`. If an edit did change the endings, put them back — this rewrites the
    whole file to one ending, so it also repairs a mixed one:
    
    ```bash
    python3 "<scripts-dir>/mo_edit.py" --set-eol auto "<Model.mo>"   # or: lf, or crlf
    ```
    
    **A mixed file follows its library, not itself.** If the file you are editing is
    mixed while the rest of the library is consistent, do not settle it on whichever
    ending dominates *inside* that file — the mixing is damage, so the file is not
    evidence about itself, and its majority leaves you with the one odd file out.
    Use the library's ending. `auto` does this for you, and reports which rule it
    applied.
    
    Creating a new `.mo`: same rule — match the sibling `.mo` files in the same
    directory or library (`--eol` accepts several paths at once), so one library does
    not end up half CRLF and half LF. Use LF only when there is nothing to match.
    
    The annotator scripts' `--write` paths already preserve the file's endings and
    warn about a mixed input, so no manual step is needed around those.
    
    ### Let the launcher own .mos/.bat and paths
    
    Do **not** hand-write `.mos` scripts, `.bat` files, or hardcode install/compiler
    paths. The bundled `scripts/wsm_run.py` handles every OS difference — it finds
    the System Modeler install and kernel binary (macOS / Windows / Linux), finds and
    loads the right MSL files, generates the `.mos`, and runs the kernel with a
    working compiler environment per platform (system clang/gcc on macOS/Linux; the
    Visual Studio dev environment via `VsDevCmd.bat` on Windows).
    See [`../scripts/README.md`](../scripts/README.md) for `WSM_HOME`, the Windows compiler prerequisites,
    and the full option table.
    
    ### When the install or compiler isn't found
    
    The launcher searches each OS's standard install locations. If it prints
    `ERROR: Could not locate a Wolfram System Modeler installation`, the install
    is in a non-standard place — ask the user for it and re-run with
    `--wsm-home "<path>"` (or have them set `WSM_HOME`).
    
    Building and simulating also need a C++ toolchain:
    
    - **Windows**: Visual Studio Build Tools. The launcher locates `VsDevCmd.bat`
      itself; if it reports the compiler environment is missing, pass
      `--vsdevcmd "<path-to-VsDevCmd.bat>"` (or set `WSM_VSDEVCMD`) and make sure
      Build Tools are installed.
    - **macOS**: the Xcode command-line tools (`xcode-select --install`).
    - **Linux**: gcc/g++.
    
    Run `python3 "<scripts-dir>/wsm_run.py" --mode info` to see what the launcher
    discovered.
    
    ### Checking the setup
    
    When the user asks whether the machine is ready for these skills, run
    `python3 <scripts-dir>/wsm_run.py --mode info` and report what it prints: the
    System Modeler installation it found and, on Windows, the compiler environment.
    If `InstallationGuide.md` sits next to the `scripts/` folder, as it does when
    the skills are installed as a plugin, it lists what each skill needs: follow its
    Steps 2, 4 and 5, and do not run the installer.
    
    ### Temporary directories
    
    The launcher works in a `_wsm_<mode>_temp/` directory
    (`_wsm_validate_temp/`, `_wsm_simulate_temp/`, `_wsm_diagnose_temp/`) and leaves
    its outputs there. It sits next to a single `.mo` file, or next to the top folder
    of a directory-form library, never inside the library. The launcher prints its
    path as `temp dir :`; `<temp-dir>` in the skills means that path. Tell the user,
    e.g.: "Working in temporary directory `_wsm_<mode>_temp/`. This will be deleted
    afterwards." Pass `--tempdir`
    to reuse one directory across models in a session.
    
    Clean up by removing the whole directory — use the user's shell:
    
    ```bash
    rm -rf "<temp-dir>"          # macOS / Linux
    # PowerShell: Remove-Item -Recurse -Force "<temp-dir>"
    ```
    
    ### Picking the model name
    
    - The user may provide a path to a `.mo` file, or you may already be working with
      one in context.
    - Extract the **model name**: the identifier after `model` on the first non-comment
      line, e.g. `model FooBar` → `FooBar`. The filename does not always match the
      model name — parse the actual `model`/`package` declaration.
    - For packages or nested models, use the **top-level** model name.
    - **Pick an instantiable model, not a package**, for any kernel call. A `package`
      cannot be validated or simulated ("Invalid instantiation … is a package") — use
      a nested model's full dotted name, e.g. `Package.Model`.
    - Pass an **absolute path** to `--model` (relative paths break as the working
      directory shifts between calls).
    - **A class that is already in a loaded library needs no `--model` at all** — give
      just the full dotted `--name` and the launcher takes it from MSL (or from a
      `--load-library` library). Use this for MSL examples rather than writing a
      wrapper model that extends one:
    
      ```bash
      python3 "<scripts-dir>/wsm_run.py" --mode diagnose \
        --name Modelica.Mechanics.MultiBody.Examples.Loops.EngineV6
      ```
    
      The temp dir then goes in the current directory. `--model` is still required
      for a class in the user's own file.
    
    ### Directory-form (multi-file) libraries
    
    A directory-form library stores one class per file with a `package.mo` at each
    level. You **cannot** validate such a class by handing the launcher only its own
    `.mo` file — the class's `within Lib;` clause needs the whole package loaded, and
    loading the single file alone fails with
    `Internal error: ... expandLibNode: Unknown library: Lib`. Instead point
    `--model` at the **library folder** (or its top `package.mo`, or any class file
    inside it) and pass the **full dotted class name** via `--name`:
    
    ```bash
    python3 "<scripts-dir>/wsm_run.py" --mode validate \
      --model "/abs/path/InvertedPendulum" \
      --name InvertedPendulum.Controller
    ```
    
    The launcher resolves any of those forms up to the library's root `package.mo`
    and loads the entire package (following `package.order`) before instantiating
    `--name`. It prints a `NOTE:` telling you which `package.mo` it loaded. Do **not**
    try to work around the unknown-library error by `--load`-ing individual files.
    
    ### Reading the JSON output
    
    The kernel writes `<mode>.out.json` into the temp dir. **It is a JSON *array* —
    take the first element**, then read:
    
    - **`status.flatten`**: `"Pass"` / `"Fail"` (the primary result for `validate`).
    - **`status.build`**: `"Pass"` / `"Fail"` — C++ compilation/linking (`simulate`).
    - **`status.result`**: simulation result status (`simulate`).
    - **`messages.errors`** / **`messages.warnings`** / **`messages.notifications`**:
      arrays (empty if none).
    - **`flat_model`** (`validate`) / **`simulation.resultFile`** (`simulate`): the
      flattened class / path to the `.mat`.
    
    See [`../scripts/README.md`](../scripts/README.md) (`wsm_run.py` section) for the full field reference.
    
    ### Checking graphic annotations
    
    A plain run does not evaluate the graphic annotations: `Icon`, `Diagram` and
    `Placement` are carried along untouched, so an error inside one cannot fail the
    run. Add `--graphics` to have them evaluated together with the model:
    
    ```bash
    python3 "<scripts-dir>/wsm_run.py" --mode validate --graphics \
      --model "<Model.mo>" --name "<Package>.<ModelName>" --timeout 90
    ```
    
    Errors then arrive through the usual `status.flatten` and `messages.errors`: a
    variable or component path that does not resolve, a misspelled shape
    (`Rectangel`) or field (`extend`), an array subscript out of bounds. This mode
    needs no C++ compiler, so it is the gate to run after editing annotations.
    
    The compiling modes (`--mode simulate`, `--mode diagnose`) additionally generate
    the model's diagram view, which evaluates the animated (`DynamicSelect`)
    expressions themselves. The launcher prints a `graphics :` line naming the
    generated view; if it was not generated it says so and exits non-zero, meaning an
    animated field could not be evaluated. It also exits non-zero, listing them, when
    an animated value falls back to its static value — typically an expression using a
    function the diagram does not support. Nothing else reports either.
    
    Evaluating the annotations is extra work for the frontend, so pass `--graphics`
    when the annotations are what you changed or are checking, not by default.
    
    Not every System Modeler version supports `--graphics`. On one that does not, the
    launcher drops it with a `NOTE:` and runs without it, so the graphic annotations are
    **not** checked; say so rather than reporting them as valid.
    
    ### MSL 4.x dialect
    
    This toolchain ships **MSL 4.x**. When authoring models, use the 4.x names — the
    3.2 names flatten with confusing "not found" errors:
    
    - units: `Modelica.Units.SI.*` (not `Modelica.SIunits.*`)
    - source frequency parameter: `f` (not `freqHz`), e.g. `SineVoltage(V=.., f=..)`
    - declare the dependency with the exact MSL version, e.g.
      `annotation(uses(Modelica(version="4.1.0")))`
    
    Run `python3 "<scripts-dir>/wsm_run.py" --mode info` to get the exact MSL
    version. `wsm_run.py` also warns on stderr if it spots a 3.2 name in the model.
    
    **When a flatten fails with `Element not found ... in Modelica...`**, the MSL
    component path is wrong (a misremembered name, not a missing install). Resolve
    the correct path with the **search-modelica-docs** skill — e.g. sine is
    `Modelica.Blocks.Sources.Sine` (not `Math.Sine`), difference is `Math.Feedback`
    (not `Math.Subtract`), and saturation is `Nonlinear.Limiter` (not
    `Nonlinear.Saturation`). **Do not** grep or walk the System Modeler install tree
    to hunt for the class.
    
    ### Using non-MSL libraries (Hydraulic, and other installed libraries)
    
    MSL is automatic (`--msl`). For **any other** library a model uses — Hydraulic, or
    anything the user installed from the Library Store — the launcher can find it for you.
    Two steps, no guessing at paths:
    
    1. **See what is installed** (bundled with System Modeler, user-installed archives, and
       any custom folders configured in Model Center):
    
       ```bash
       python3 "<scripts-dir>/wsm_run.py" --mode libraries
       # add --json for a machine-readable array; each row has name/version/source/package
       ```
    
       To get just one library's package path (e.g. for a manual `--load`):
       `--mode libraries --library Hydraulic` (add `--library-version 2.1` to pin a version).
    
    2. **Load it into a build** by name — add `--load-library <Name>` to a validate /
       simulate / diagnose run (repeatable; pin a version with `Name==Ver`):
    
       ```bash
       python3 "<scripts-dir>/wsm_run.py" --mode validate \
         --model "<path>/M.mo" --name M --load-library Hydraulic
       ```
    
       The launcher resolves the library (bundled → user-installed → Model-Center custom
       path, newest version wins) and `loadFile`s it before the model. A library usually
       pulls in MSL, so keep MSL on (auto, or `--msl yes`). Override a lookup with
       `$WSM_LIBRARY_<NAME>` (e.g. `WSM_LIBRARY_HYDRAULIC=/path/to/package.moe`), or fall
       back to an explicit `--load <path-to-package.mo|.moe>`.
    

Comments (0)

Sign in to join the conversation.

No comments yet.

Reviews (0)

No reviews yet.