Claude Skill

simulate-modelica

Simulate Modelica models (.mo files) with WSMKernelX — compiles to C++, builds, and runs the simulation (no plotting; to plot the results too, use simulate-and-plot-modelica). Use this skill whenever the user asks to simulate a Modelica model, run a simulation, or get simulation

LLM Mart · 0 points · 0 views 0 listing impressions 0 install-command copies
Download wolframresearch-system-modeler-ai-toolkit-simulate-modelica-7f6f400.zip · 9 KB

Install

skills CLI npx skills add https://github.com/WolframResearch/system-modeler-ai-toolkit/tree/main/simulate-modelica
Claude Code claude plugin marketplace add https://llmmart.ai/marketplace.json && claude plugin install wolframresearch-system-modeler-ai-toolkit@llmmart
Git git clone https://github.com/WolframResearch/system-modeler-ai-toolkit.git

The skills CLI installs just this skill, for any of its supported agents. Claude Code installs the whole wolframresearch/system-modeler-ai-toolkit collection as a plugin from our marketplace. Git is the plain clone.

Skill manifest

Simulate Modelica Model

This skill simulates Modelica models (.mo files) with WSMKernelX: it flattens the model, generates C++ code, compiles it, and runs the simulation. It produces a .mat results file.

Before you run anything

This skill drives WSMKernelX through the shared launcher ../scripts/wsm_run.py. Read the shared-conventions appendix at the end of this file first — launcher resolution, the Windows-vs-Unix shell/Python rules, the temp-dir and cleanup conventions, the JSON-array output gotcha, and the MSL 4.x dialect notes that every step below assumes.

The launcher works in _wsm_simulate_temp/ (next to the .mo file, or next to a directory-form library) and leaves simulate.out.json and the .mat there. Tell the user: "Working in temporary directory _wsm_simulate_temp/. This will be deleted after simulation."

Workflow

1. Identify the model file and name

Identify the .mo file and extract the model name — see Appendix → Picking the model name. For a directory-form (multi-file) library, point --model at the library folder (not one class file) and pass the full dotted --name — see Appendix → Directory-form (multi-file) libraries.

2. Run the simulation

python3 "<scripts-dir>/wsm_run.py" --mode simulate \
  --model "<path-to-ModelFile.mo>" --name ModelName --timeout 180

Terser loop: add --quiet to print only a one-line outcome (status + integration time + result file) instead of the full kernel log, and --report "Vout,x.T" to print a compact min/max/mean/pp/final table of those variables straight from the result .mat — so the common "simulate then inspect a few values" step is a single call. (--report runs mat_summary.py, which you can also call standalone on any .mat.)

The launcher auto-detects MSL usage and loads the right version; force it with --msl yes|no or --msl-version 4.1.0. If the model uses an installed non-MSL library (e.g. Hydraulic), add --load-library <Name> — see Appendix → Using non-MSL libraries. Timeout: allow up to 180 seconds — compilation and simulation of complex models can take time.

Compiling needs a per-OS C++ toolchain (Visual Studio Build Tools / Xcode CLT / gcc) — the launcher finds it; if it can't, see Appendix → When the install or compiler isn't found.

3. Parse the output

WSMKernelX writes structured results to simulate.out.json in the temp directory — a JSON array; take the first element. Check status.flatten, status.build, and status.result in that order; on success simulation.resultFile holds the path to the .mat (also printed as a SimulationResult record). Field reference: Appendix → Reading the JSON output.

4. Report results

Summarize clearly:

  • Pass: State the simulation completed successfully. Report key stats from the log (integration time, number of events, number of function evaluations).
  • Build Fail: The C++ compilation or linking failed. Show the build errors.
  • Flatten Fail: The model has structural errors. Show the flatten errors.
  • Fatal error: exception ...(_) / no out.json: a normal error (assertion, parameter/init, type, lookup) that escaped catching — not a crash. Read the launcher's === actual kernel diagnostic === block, which prints the recovered message; don't assume a compiler bug.

A clean "Pass" does not mean the result is correct. A model can compile and simulate with zero errors while being physically wrong (mis-biased circuit with ~0 output, a state pinned at a saturation limit, a node that silently went NaN). After a successful run, sanity-check the trajectories:

python3 "<scripts-dir>/check_sanity.py" "<temp-dir>/<Model>.mat"

It flags NaN/Inf, variables that never move, and signals that swung then flatlined (possible saturation / mis-bias). Treat the flags as prompts to inspect operating points, not as failures. (It self-provisions DyMat/numpy.)

When you simulate a system to settle, get the operating point — a domain-neutral steady-state report that works for thermal, hydraulic, mechanical, electrical, ... models. It checks each state's derivative to report whether the run reached equilibrium (and lists states still drifting), then prints the settled values:

python3 "<scripts-dir>/op_report.py" "<temp-dir>/<Model>.mat" --vars tank.T pump.dp

Domain add-ons fire automatically when applicable — e.g. for circuits it also classifies BJT regions (ACTIVE / SATURATED / CUTOFF from Vbe/Vbc), catching mis-bias that no error would report. (Self-provisions DyMat/numpy.)

4b. Parameter studies WITHOUT recompiling (--override / --sweep)

To try different parameter values, do not rebuild or hand-write wrapper models. The launcher builds once and re-runs the compiled executable per value by editing the .sim init file's value= attribute:

# one value set
python3 "<scripts-dir>/wsm_run.py" --mode simulate --model M.mo --name Pkg.M \
  --override "kfb=0.04,I0=45e-6"
# sweep one parameter (one .mat per value), holding others via --override
python3 "<scripts-dir>/wsm_run.py" --mode simulate --model M.mo --name Pkg.M \
  --sweep "I0=12e-6,32.5e-6,90e-6"

Each run writes run_<label>.mat in the temp dir; plot/compare them directly. Caveat (this is enforced): only parameters with initType="exact" in the .sim can be overridden this way. Structural parameters (used in array sizes, conditional components, etc.) are constant-folded into the compiled code — the launcher detects these from the .sim and warns that they need a real rebuild (set them in the model or build model X = Pkg.M(param=value)).

5. Clean up

Remove _wsm_simulate_temp/ entirely — commands per OS: Appendix → Temporary directories.

Edge cases

  • Packages / name mismatches: parse the actual model/package declaration, not the filename — see Appendix → Picking the model name.
  • Unknown library: X on a multi-file library: you pointed --model at a single class file; point it at the library folder instead — see Appendix → Directory-form (multi-file) libraries.
  • Element not found ... in Modelica...: the MSL path is wrong — look up the right one with the search-modelica-docs skill, don't grep the install tree. See Appendix → MSL 4.x dialect.
  • WSMKernelX or compiler not found: see Appendix → When the install or compiler isn't found.
  • Simulation times out or stalls at initialization: First distinguish build from solve — check whether the .exe was produced (build done) and whether any result rows were written. If it builds but the solver makes no progress:
    1. Re-run with a short StopTime (override the model's experiment annotation, or use a small wrapper model) to confirm it integrates at all before committing to a long run.
    2. If it stalls at/near t=0, suspect a nonlinear algebraic loop with no dynamic states — common in high-gain feedback (active circuits, control loops) where every variable is algebraic. Run the diagnose-modelica skill, then the check_singularity.py / check_tearing.py scripts (documented in ../scripts/README.md) — they reveal the offending algebraic systems.
    3. The usual physical fix, in any domain, is to restore the small storage element the idealized model dropped — a device capacitance on an electrical node, a compliant joint for a rigid coupling, a heat capacity on a thermal port, a small volume at a fluid junction. It turns the algebraic loop into an integrable ODE and defines the operating point. The diagnose-modelica skill covers where to put it, and the two placements that look right and are not.
    4. As a numerical lever, loosen tolerance or raise --timeout, but prefer fixing the model structure — a model that needs a huge timeout for a short horizon is usually telling you something.

Appendix: shared conventions for the Modelica skills

Shared by every Modelica skill that drives WSMKernelX through the bundled launcher; inlined here at release time. For the CLI/option reference, environment variables (WSM_HOME, WSM_VSDEVCMD), install discovery, and the analysis scripts, see ../scripts/README.md.

These are conventions, not a workflow. Knowing how to call the tools is not the same as knowing which to call, in what order, and how to tell a good answer from a plausible one — that lives in the skills, one per job. Invoke the one that owns the step you are on, including when it is not the one you started from: a job that begins in one skill routinely runs into something another one owns, and the whole toolkit is available the entire time.

What you run into Skill
About to write or restructure a model or library — including one you decided to build yourself modelica-model-architecture first
A .mo you just wrote or edited; a structural error validate-modelica
You need results simulate-modelica (simulate-and-plot-modelica to plot them too)
A run that must go in real time, take input changes while it runs, or be driven from another program simulate-modelica-realtime
It validates but will not build; it runs far too slowly; it gives an answer you cannot account for; you need its states, equations or blocks diagnose-modelica
The launcher reports a compiler failure — an internal error, generated code that does not compile, a simulator internal error or a kernel crash minimize-modelica-bug
A Modelica language or MSL question you would otherwise answer from memory search-modelica-docs
Sweeps, limit checks, calibration, custom result analysis wolfram-language-modelica
No icons, or no diagram layout annotate-modelica-graphics
Plots that should live in the model and reopen with it annotate-modelica-plots
Interactive sliders in Simulation Center's Explore view annotate-control-panel
3D MultiBody animation annotate-modelica-animation
A hydraulic circuit create-hydraulic-model

Locating the launcher

<scripts-dir> (used throughout the skills) is the shared scripts/ folder. Some installs symlink the skill directories without it, so resolve it in this order and use the first that exists:

  1. $WSM_SKILLS_SCRIPTS (bash) or $env:WSM_SKILLS_SCRIPTS (PowerShell), if set.
  2. ../scripts relative to the skill directory — in a normal install ../scripts/wsm_run.py already exists, so use that path directly; do not run a shell probe to "resolve" it.
  3. The folder you cloned or unzipped the skills from, e.g. .../system-modeler-ai-toolkit/scripts.
  4. Last resort, search the home directory:
    • PowerShell: Get-ChildItem $HOME -Recurse -Filter wsm_run.py -ErrorAction SilentlyContinue | Select-Object -First 1
    • bash/zsh: find ~ -name wsm_run.py -path '*scripts*' 2>/dev/null | head -1

If only #4 finds it, the install is missing the scripts/ link — tell the user to run install.sh (or install.ps1) from the repo, which links scripts/ too.

Shell and Python

On Windows, use PowerShell. The Git-Bash/cygwin layer may be broken (even ls/find can be absent, giving a misleading "exit 127 / command not found"). Run wsm_run.py with python (not python3); those calls are single-line and shell-agnostic. For cleanup use Remove-Item -Recurse -Force, not rm -rf. On macOS/Linux any POSIX shell is fine and python3 is the usual name.

For your own analysis, borrow the scripts' interpreter. Whatever python3 you get is unlikely to have numpy or scipy, and installing into it is both rude and often blocked. The analysis scripts run under a managed virtualenv with numpy, scipy, matplotlib and DyMat; python3 <scripts-dir>/bootstrap_env.py makes sure they are installed there and prints its interpreter path. Use that interpreter for ad-hoc post-processing rather than discovering package by package what the system one lacks.

Line endings in .mo files

Modelica models are written on Windows, macOS and Linux alike, so a .mo file may use CRLF or LF. Neither is the "right" one. Match whatever the file already has, and never leave a file with a mix of both — a mixed file shows up as a whole-file diff the moment anything rewrites it, burying the real change.

When you edit a .mo yourself with the Write/Edit tools (rather than through one of the annotator scripts), those tools write back exactly the text you give them, so an edit in the other style silently mixes the file. Check before, and check again after:

python3 "<scripts-dir>/mo_edit.py" --eol "<Model.mo>"

It prints LF, CRLF, MIXED (crlf=N lf=M) or NONE, and exits non-zero on MIXED. If an edit did change the endings, put them back — this rewrites the whole file to one ending, so it also repairs a mixed one:

python3 "<scripts-dir>/mo_edit.py" --set-eol auto "<Model.mo>"   # or: lf, or crlf

A mixed file follows its library, not itself. If the file you are editing is mixed while the rest of the library is consistent, do not settle it on whichever ending dominates inside that file — the mixing is damage, so the file is not evidence about itself, and its majority leaves you with the one odd file out. Use the library's ending. auto does this for you, and reports which rule it applied.

Creating a new .mo: same rule — match the sibling .mo files in the same directory or library (--eol accepts several paths at once), so one library does not end up half CRLF and half LF. Use LF only when there is nothing to match.

The annotator scripts' --write paths already preserve the file's endings and warn about a mixed input, so no manual step is needed around those.

Let the launcher own .mos/.bat and paths

Do not hand-write .mos scripts, .bat files, or hardcode install/compiler paths. The bundled scripts/wsm_run.py handles every OS difference — it finds the System Modeler install and kernel binary (macOS / Windows / Linux), finds and loads the right MSL files, generates the .mos, and runs the kernel with a working compiler environment per platform (system clang/gcc on macOS/Linux; the Visual Studio dev environment via VsDevCmd.bat on Windows). See ../scripts/README.md for WSM_HOME, the Windows compiler prerequisites, and the full option table.

When the install or compiler isn't found

The launcher searches each OS's standard install locations. If it prints ERROR: Could not locate a Wolfram System Modeler installation, the install is in a non-standard place — ask the user for it and re-run with --wsm-home "<path>" (or have them set WSM_HOME).

Building and simulating also need a C++ toolchain:

  • Windows: Visual Studio Build Tools. The launcher locates VsDevCmd.bat itself; if it reports the compiler environment is missing, pass --vsdevcmd "<path-to-VsDevCmd.bat>" (or set WSM_VSDEVCMD) and make sure Build Tools are installed.
  • macOS: the Xcode command-line tools (xcode-select --install).
  • Linux: gcc/g++.

Run python3 "<scripts-dir>/wsm_run.py" --mode info to see what the launcher discovered.

Checking the setup

When the user asks whether the machine is ready for these skills, run python3 <scripts-dir>/wsm_run.py --mode info and report what it prints: the System Modeler installation it found and, on Windows, the compiler environment. If InstallationGuide.md sits next to the scripts/ folder, as it does when the skills are installed as a plugin, it lists what each skill needs: follow its Steps 2, 4 and 5, and do not run the installer.

Temporary directories

The launcher works in a _wsm_<mode>_temp/ directory (_wsm_validate_temp/, _wsm_simulate_temp/, _wsm_diagnose_temp/) and leaves its outputs there. It sits next to a single .mo file, or next to the top folder of a directory-form library, never inside the library. The launcher prints its path as temp dir :; <temp-dir> in the skills means that path. Tell the user, e.g.: "Working in temporary directory _wsm_<mode>_temp/. This will be deleted afterwards." Pass --tempdir to reuse one directory across models in a session.

Clean up by removing the whole directory — use the user's shell:

rm -rf "<temp-dir>"          # macOS / Linux
# PowerShell: Remove-Item -Recurse -Force "<temp-dir>"

Picking the model name

  • The user may provide a path to a .mo file, or you may already be working with one in context.

  • Extract the model name: the identifier after model on the first non-comment line, e.g. model FooBar → FooBar. The filename does not always match the model name — parse the actual model/package declaration.

  • For packages or nested models, use the top-level model name.

  • Pick an instantiable model, not a package, for any kernel call. A package cannot be validated or simulated ("Invalid instantiation … is a package") — use a nested model's full dotted name, e.g. Package.Model.

  • Pass an absolute path to --model (relative paths break as the working directory shifts between calls).

  • A class that is already in a loaded library needs no --model at all — give just the full dotted --name and the launcher takes it from MSL (or from a --load-library library). Use this for MSL examples rather than writing a wrapper model that extends one:

    python3 "<scripts-dir>/wsm_run.py" --mode diagnose \
      --name Modelica.Mechanics.MultiBody.Examples.Loops.EngineV6
    

    The temp dir then goes in the current directory. --model is still required for a class in the user's own file.

Directory-form (multi-file) libraries

A directory-form library stores one class per file with a package.mo at each level. You cannot validate such a class by handing the launcher only its own .mo file — the class's within Lib; clause needs the whole package loaded, and loading the single file alone fails with Internal error: ... expandLibNode: Unknown library: Lib. Instead point --model at the library folder (or its top package.mo, or any class file inside it) and pass the full dotted class name via --name:

python3 "<scripts-dir>/wsm_run.py" --mode validate \
  --model "/abs/path/InvertedPendulum" \
  --name InvertedPendulum.Controller

The launcher resolves any of those forms up to the library's root package.mo and loads the entire package (following package.order) before instantiating --name. It prints a NOTE: telling you which package.mo it loaded. Do not try to work around the unknown-library error by --load-ing individual files.

Reading the JSON output

The kernel writes <mode>.out.json into the temp dir. It is a JSON array — take the first element, then read:

  • status.flatten: "Pass" / "Fail" (the primary result for validate).
  • status.build: "Pass" / "Fail" — C++ compilation/linking (simulate).
  • status.result: simulation result status (simulate).
  • messages.errors / messages.warnings / messages.notifications: arrays (empty if none).
  • flat_model (validate) / simulation.resultFile (simulate): the flattened class / path to the .mat.

See ../scripts/README.md (wsm_run.py section) for the full field reference.

Checking graphic annotations

A plain run does not evaluate the graphic annotations: Icon, Diagram and Placement are carried along untouched, so an error inside one cannot fail the run. Add --graphics to have them evaluated together with the model:

python3 "<scripts-dir>/wsm_run.py" --mode validate --graphics \
  --model "<Model.mo>" --name "<Package>.<ModelName>" --timeout 90

Errors then arrive through the usual status.flatten and messages.errors: a variable or component path that does not resolve, a misspelled shape (Rectangel) or field (extend), an array subscript out of bounds. This mode needs no C++ compiler, so it is the gate to run after editing annotations.

The compiling modes (--mode simulate, --mode diagnose) additionally generate the model's diagram view, which evaluates the animated (DynamicSelect) expressions themselves. The launcher prints a graphics : line naming the generated view; if it was not generated it says so and exits non-zero, meaning an animated field could not be evaluated. It also exits non-zero, listing them, when an animated value falls back to its static value — typically an expression using a function the diagram does not support. Nothing else reports either.

Evaluating the annotations is extra work for the frontend, so pass --graphics when the annotations are what you changed or are checking, not by default.

Not every System Modeler version supports --graphics. On one that does not, the launcher drops it with a NOTE: and runs without it, so the graphic annotations are not checked; say so rather than reporting them as valid.

MSL 4.x dialect

This toolchain ships MSL 4.x. When authoring models, use the 4.x names — the 3.2 names flatten with confusing "not found" errors:

  • units: Modelica.Units.SI.* (not Modelica.SIunits.*)
  • source frequency parameter: f (not freqHz), e.g. SineVoltage(V=.., f=..)
  • declare the dependency with the exact MSL version, e.g. annotation(uses(Modelica(version="4.1.0")))

Run python3 "<scripts-dir>/wsm_run.py" --mode info to get the exact MSL version. wsm_run.py also warns on stderr if it spots a 3.2 name in the model.

When a flatten fails with Element not found ... in Modelica..., the MSL component path is wrong (a misremembered name, not a missing install). Resolve the correct path with the search-modelica-docs skill — e.g. sine is Modelica.Blocks.Sources.Sine (not Math.Sine), difference is Math.Feedback (not Math.Subtract), and saturation is Nonlinear.Limiter (not Nonlinear.Saturation). Do not grep or walk the System Modeler install tree to hunt for the class.

Using non-MSL libraries (Hydraulic, and other installed libraries)

MSL is automatic (--msl). For any other library a model uses — Hydraulic, or anything the user installed from the Library Store — the launcher can find it for you. Two steps, no guessing at paths:

  1. See what is installed (bundled with System Modeler, user-installed archives, and any custom folders configured in Model Center):

    python3 "<scripts-dir>/wsm_run.py" --mode libraries
    # add --json for a machine-readable array; each row has name/version/source/package
    

    To get just one library's package path (e.g. for a manual --load): --mode libraries --library Hydraulic (add --library-version 2.1 to pin a version).

  2. Load it into a build by name — add --load-library <Name> to a validate / simulate / diagnose run (repeatable; pin a version with Name==Ver):

    python3 "<scripts-dir>/wsm_run.py" --mode validate \
      --model "<path>/M.mo" --name M --load-library Hydraulic
    

    The launcher resolves the library (bundled → user-installed → Model-Center custom path, newest version wins) and loadFiles it before the model. A library usually pulls in MSL, so keep MSL on (auto, or --msl yes). Override a lookup with $WSM_LIBRARY_<NAME> (e.g. WSM_LIBRARY_HYDRAULIC=/path/to/package.moe), or fall back to an explicit --load <path-to-package.mo|.moe>.

Files (system-modeler-ai-toolkit)
  • SKILL.md 24.4 KB
    ---
    name: simulate-modelica
    description: "Simulate Modelica models (.mo files) with WSMKernelX — compiles to C++, builds, and runs the simulation (no plotting; to plot the results too, use simulate-and-plot-modelica). Use this skill whenever the user asks to simulate a Modelica model, run a simulation, or get simulation results or time-domain behavior. Triggers on phrases like 'simulate this model', 'run the simulation', 'get simulation results'. Use it also when running a model is a step in a larger job you took on yourself — verifying a port, a datasheet claim or a hand-written implementation against a model built for the purpose — even if the request never mentioned Modelica. If the request also involves analysis — limits/requirements, violations, parameter sweeps, Monte Carlo, calibration — prefer wolfram-language-modelica when Wolfram Language is available."
    ---
    
    # Simulate Modelica Model
    
    This skill simulates Modelica models (.mo files) with WSMKernelX: it flattens the model, generates C++ code, compiles it, and runs the simulation. It produces a `.mat` results file.
    
    ## Before you run anything
    
    This skill drives WSMKernelX through the shared launcher
    `../scripts/wsm_run.py`. **Read [the shared-conventions appendix at the end of this file](#appendix-shared-conventions-for-the-modelica-skills)
    first** — launcher resolution, the Windows-vs-Unix shell/Python rules, the
    temp-dir and cleanup conventions, the JSON-array output gotcha, and the MSL 4.x
    dialect notes that every step below assumes.
    
    The launcher works in `_wsm_simulate_temp/` (next to the `.mo` file, or next to a
    directory-form library) and leaves
    `simulate.out.json` and the `.mat` there. Tell the user: "Working in temporary
    directory `_wsm_simulate_temp/`. This will be deleted after simulation."
    
    ## Workflow
    
    ### 1. Identify the model file and name
    
    Identify the `.mo` file and extract the **model name** — see [Appendix → Picking the model name](#picking-the-model-name). For a **directory-form (multi-file) library**, point `--model` at the library folder (not one class file) and pass the full dotted `--name` — see [Appendix → Directory-form (multi-file) libraries](#directory-form-multi-file-libraries).
    
    ### 2. Run the simulation
    
    ```bash
    python3 "<scripts-dir>/wsm_run.py" --mode simulate \
      --model "<path-to-ModelFile.mo>" --name ModelName --timeout 180
    ```
    
    **Terser loop:** add `--quiet` to print only a one-line outcome (status + integration
    time + result file) instead of the full kernel log, and `--report "Vout,x.T"` to print a
    compact min/max/mean/pp/final table of those variables straight from the result `.mat` —
    so the common "simulate then inspect a few values" step is a single call. (`--report`
    runs `mat_summary.py`, which you can also call standalone on any `.mat`.)
    
    The launcher auto-detects MSL usage and loads the right version; force it with
    `--msl yes|no` or `--msl-version 4.1.0`. If the model uses an installed non-MSL
    library (e.g. `Hydraulic`), add `--load-library <Name>` — see
    [Appendix → Using non-MSL libraries](#using-non-msl-libraries-hydraulic-and-other-installed-libraries).
    Timeout: allow up to 180 seconds — compilation and simulation of complex models can take time.
    
    Compiling needs a per-OS C++ toolchain (Visual Studio Build Tools / Xcode CLT /
    gcc) — the launcher finds it; if it can't, see
    [Appendix → When the install or compiler isn't found](#when-the-install-or-compiler-isnt-found).
    
    ### 3. Parse the output
    
    WSMKernelX writes structured results to `simulate.out.json` in the temp
    directory — a JSON *array*; take the first element. Check **`status.flatten`**,
    **`status.build`**, and **`status.result`** in that order; on success
    `simulation.resultFile` holds the path to the `.mat` (also printed as a
    `SimulationResult` record). Field reference:
    [Appendix → Reading the JSON output](#reading-the-json-output).
    
    ### 4. Report results
    
    Summarize clearly:
    - **Pass**: State the simulation completed successfully. Report key stats from the log (integration time, number of events, number of function evaluations).
    - **Build Fail**: The C++ compilation or linking failed. Show the build errors.
    - **Flatten Fail**: The model has structural errors. Show the flatten errors.
    - **`Fatal error: exception ...(_)` / no out.json**: a normal error (assertion, parameter/init, type, lookup) that escaped catching — not a crash. Read the launcher's `=== actual kernel diagnostic ===` block, which prints the recovered message; don't assume a compiler bug.
    
    **A clean "Pass" does not mean the result is correct.** A model can compile and
    simulate with zero errors while being physically wrong (mis-biased circuit with
    ~0 output, a state pinned at a saturation limit, a node that silently went NaN).
    After a successful run, sanity-check the trajectories:
    
    ```bash
    python3 "<scripts-dir>/check_sanity.py" "<temp-dir>/<Model>.mat"
    ```
    
    It flags NaN/Inf, variables that never move, and signals that swung then
    flatlined (possible saturation / mis-bias). Treat the flags as prompts to
    inspect operating points, not as failures. (It self-provisions DyMat/numpy.)
    
    When you simulate a system to settle, get the **operating point** — a domain-neutral
    steady-state report that works for thermal, hydraulic, mechanical, electrical, ...
    models. It checks each state's derivative to report whether the run reached
    equilibrium (and lists states still drifting), then prints the settled values:
    
    ```bash
    python3 "<scripts-dir>/op_report.py" "<temp-dir>/<Model>.mat" --vars tank.T pump.dp
    ```
    
    Domain add-ons fire automatically when applicable — e.g. for circuits it also
    classifies BJT regions (ACTIVE / SATURATED / CUTOFF from `Vbe`/`Vbc`), catching
    mis-bias that no error would report. (Self-provisions DyMat/numpy.)
    
    ### 4b. Parameter studies WITHOUT recompiling (`--override` / `--sweep`)
    
    To try different parameter values, do **not** rebuild or hand-write wrapper models.
    The launcher builds once and re-runs the compiled executable per value by editing the
    `.sim` init file's `value=` attribute:
    
    ```bash
    # one value set
    python3 "<scripts-dir>/wsm_run.py" --mode simulate --model M.mo --name Pkg.M \
      --override "kfb=0.04,I0=45e-6"
    # sweep one parameter (one .mat per value), holding others via --override
    python3 "<scripts-dir>/wsm_run.py" --mode simulate --model M.mo --name Pkg.M \
      --sweep "I0=12e-6,32.5e-6,90e-6"
    ```
    
    Each run writes `run_<label>.mat` in the temp dir; plot/compare them directly.
    **Caveat (this is enforced):** only parameters with `initType="exact"` in the `.sim`
    can be overridden this way. **Structural parameters** (used in array sizes, conditional
    components, etc.) are constant-folded into the compiled code — the launcher detects
    these from the `.sim` and warns that they need a real rebuild (set them in the model or
    build `model X = Pkg.M(param=value)`).
    
    ### 5. Clean up
    
    Remove `_wsm_simulate_temp/` entirely — commands per OS: [Appendix → Temporary directories](#temporary-directories).
    
    ## Edge cases
    
    - **Packages / name mismatches**: parse the actual `model`/`package` declaration, not the filename — see [Appendix → Picking the model name](#picking-the-model-name).
    - **`Unknown library: X` on a multi-file library**: you pointed `--model` at a single class file; point it at the library folder instead — see [Appendix → Directory-form (multi-file) libraries](#directory-form-multi-file-libraries).
    - **`Element not found ... in Modelica...`**: the MSL path is wrong — look up the right one with the `search-modelica-docs` skill, don't grep the install tree. See [Appendix → MSL 4.x dialect](#msl-4x-dialect).
    - **WSMKernelX or compiler not found**: see [Appendix → When the install or compiler isn't found](#when-the-install-or-compiler-isnt-found).
    - **Simulation times out or stalls at initialization**: First distinguish *build* from *solve* — check whether the `.exe` was produced (build done) and whether any result rows were written. If it builds but the solver makes no progress:
      1. Re-run with a short `StopTime` (override the model's `experiment` annotation, or use a small wrapper model) to confirm it integrates *at all* before committing to a long run.
      2. If it stalls at/near `t=0`, suspect a **nonlinear algebraic loop with no dynamic states** — common in high-gain feedback (active circuits, control loops) where every variable is algebraic. Run the `diagnose-modelica` skill, then the `check_singularity.py` / `check_tearing.py` scripts (documented in [`../scripts/README.md`](../scripts/README.md)) — they reveal the offending algebraic systems.
      3. The usual physical fix, in any domain, is to restore the small **storage element the idealized model dropped** — a device capacitance on an electrical node, a compliant joint for a rigid coupling, a heat capacity on a thermal port, a small volume at a fluid junction. It turns the algebraic loop into an integrable ODE and defines the operating point. The `diagnose-modelica` skill covers where to put it, and the two placements that look right and are not.
      4. As a numerical lever, loosen tolerance or raise `--timeout`, but prefer fixing the model structure — a model that needs a huge timeout for a short horizon is usually telling you something.
    
    ---
    
    ## Appendix: shared conventions for the Modelica skills
    
    > *Shared by every Modelica skill that drives WSMKernelX through the
    > bundled launcher; inlined here at release time. For the CLI/option
    > reference, environment variables (`WSM_HOME`, `WSM_VSDEVCMD`),
    > install discovery, and the analysis scripts, see
    > [`../scripts/README.md`](../scripts/README.md).*
    
    **These are conventions, not a workflow.** Knowing how to call the tools is not
    the same as knowing which to call, in what order, and how to tell a good answer
    from a plausible one — that lives in the skills, one per job. Invoke the one that
    owns the step you are on, **including when it is not the one you started from**:
    a job that begins in one skill routinely runs into something another one owns,
    and the whole toolkit is available the entire time.
    
    | What you run into | Skill |
    |---|---|
    | About to write or restructure a model or library — including one you decided to build yourself | `modelica-model-architecture` **first** |
    | A `.mo` you just wrote or edited; a structural error | `validate-modelica` |
    | You need results | `simulate-modelica` (`simulate-and-plot-modelica` to plot them too) |
    | A run that must go in real time, take input changes while it runs, or be driven from another program | `simulate-modelica-realtime` |
    | It validates but will not build; it runs far too slowly; it gives an answer you cannot account for; you need its states, equations or blocks | `diagnose-modelica` |
    | The launcher reports a `compiler failure` — an internal error, generated code that does not compile, a simulator internal error or a kernel crash | `minimize-modelica-bug` |
    | A Modelica language or MSL question you would otherwise answer from memory | `search-modelica-docs` |
    | Sweeps, limit checks, calibration, custom result analysis | `wolfram-language-modelica` |
    | No icons, or no diagram layout | `annotate-modelica-graphics` |
    | Plots that should live in the model and reopen with it | `annotate-modelica-plots` |
    | Interactive sliders in Simulation Center's Explore view | `annotate-control-panel` |
    | 3D MultiBody animation | `annotate-modelica-animation` |
    | A hydraulic circuit | `create-hydraulic-model` |
    
    ### Locating the launcher
    
    `<scripts-dir>` (used throughout the skills) is the shared `scripts/` folder.
    Some installs symlink the skill directories without it, so resolve it in this
    order and use the first that exists:
    
    1. `$WSM_SKILLS_SCRIPTS` (bash) or `$env:WSM_SKILLS_SCRIPTS` (PowerShell), if set.
    2. `../scripts` relative to the skill directory — in a normal install
       `../scripts/wsm_run.py` already exists, so use that path directly; **do not run
       a shell probe to "resolve" it.**
    3. The folder you cloned or unzipped the skills from, e.g.
       `.../system-modeler-ai-toolkit/scripts`.
    4. Last resort, search the home directory:
       - PowerShell: `Get-ChildItem $HOME -Recurse -Filter wsm_run.py -ErrorAction SilentlyContinue | Select-Object -First 1`
       - bash/zsh: `find ~ -name wsm_run.py -path '*scripts*' 2>/dev/null | head -1`
    
    If only #4 finds it, the install is missing the `scripts/` link — tell the user
    to run `install.sh` (or `install.ps1`) from the repo, which links `scripts/` too.
    
    ### Shell and Python
    
    **On Windows, use PowerShell.** The Git-Bash/cygwin layer may be broken (even
    `ls`/`find` can be absent, giving a misleading "exit 127 / command not found").
    Run `wsm_run.py` with `python` (not `python3`); those calls are single-line and
    shell-agnostic. For cleanup use `Remove-Item -Recurse -Force`, not `rm -rf`.
    On macOS/Linux any POSIX shell is fine and `python3` is the usual name.
    
    **For your own analysis, borrow the scripts' interpreter.** Whatever `python3`
    you get is unlikely to have numpy or scipy, and installing into it is both rude
    and often blocked. The analysis scripts run under a managed virtualenv with
    numpy, scipy, matplotlib and DyMat; `python3 <scripts-dir>/bootstrap_env.py`
    makes sure they are installed there and prints its interpreter path. Use that
    interpreter for ad-hoc post-processing rather than discovering package by
    package what the system one lacks.
    
    ### Line endings in .mo files
    
    Modelica models are written on Windows, macOS and Linux alike, so a `.mo` file
    may use CRLF or LF. **Neither is the "right" one.** Match whatever the file
    already has, and never leave a file with a mix of both — a mixed file shows up
    as a whole-file diff the moment anything rewrites it, burying the real change.
    
    When you edit a `.mo` yourself with the Write/Edit tools (rather than through one
    of the annotator scripts), those tools write back exactly the text you give them,
    so an edit in the other style silently mixes the file. Check before, and check
    again after:
    
    ```bash
    python3 "<scripts-dir>/mo_edit.py" --eol "<Model.mo>"
    ```
    
    It prints `LF`, `CRLF`, `MIXED (crlf=N lf=M)` or `NONE`, and exits non-zero on
    `MIXED`. If an edit did change the endings, put them back — this rewrites the
    whole file to one ending, so it also repairs a mixed one:
    
    ```bash
    python3 "<scripts-dir>/mo_edit.py" --set-eol auto "<Model.mo>"   # or: lf, or crlf
    ```
    
    **A mixed file follows its library, not itself.** If the file you are editing is
    mixed while the rest of the library is consistent, do not settle it on whichever
    ending dominates *inside* that file — the mixing is damage, so the file is not
    evidence about itself, and its majority leaves you with the one odd file out.
    Use the library's ending. `auto` does this for you, and reports which rule it
    applied.
    
    Creating a new `.mo`: same rule — match the sibling `.mo` files in the same
    directory or library (`--eol` accepts several paths at once), so one library does
    not end up half CRLF and half LF. Use LF only when there is nothing to match.
    
    The annotator scripts' `--write` paths already preserve the file's endings and
    warn about a mixed input, so no manual step is needed around those.
    
    ### Let the launcher own .mos/.bat and paths
    
    Do **not** hand-write `.mos` scripts, `.bat` files, or hardcode install/compiler
    paths. The bundled `scripts/wsm_run.py` handles every OS difference — it finds
    the System Modeler install and kernel binary (macOS / Windows / Linux), finds and
    loads the right MSL files, generates the `.mos`, and runs the kernel with a
    working compiler environment per platform (system clang/gcc on macOS/Linux; the
    Visual Studio dev environment via `VsDevCmd.bat` on Windows).
    See [`../scripts/README.md`](../scripts/README.md) for `WSM_HOME`, the Windows compiler prerequisites,
    and the full option table.
    
    ### When the install or compiler isn't found
    
    The launcher searches each OS's standard install locations. If it prints
    `ERROR: Could not locate a Wolfram System Modeler installation`, the install
    is in a non-standard place — ask the user for it and re-run with
    `--wsm-home "<path>"` (or have them set `WSM_HOME`).
    
    Building and simulating also need a C++ toolchain:
    
    - **Windows**: Visual Studio Build Tools. The launcher locates `VsDevCmd.bat`
      itself; if it reports the compiler environment is missing, pass
      `--vsdevcmd "<path-to-VsDevCmd.bat>"` (or set `WSM_VSDEVCMD`) and make sure
      Build Tools are installed.
    - **macOS**: the Xcode command-line tools (`xcode-select --install`).
    - **Linux**: gcc/g++.
    
    Run `python3 "<scripts-dir>/wsm_run.py" --mode info` to see what the launcher
    discovered.
    
    ### Checking the setup
    
    When the user asks whether the machine is ready for these skills, run
    `python3 <scripts-dir>/wsm_run.py --mode info` and report what it prints: the
    System Modeler installation it found and, on Windows, the compiler environment.
    If `InstallationGuide.md` sits next to the `scripts/` folder, as it does when
    the skills are installed as a plugin, it lists what each skill needs: follow its
    Steps 2, 4 and 5, and do not run the installer.
    
    ### Temporary directories
    
    The launcher works in a `_wsm_<mode>_temp/` directory
    (`_wsm_validate_temp/`, `_wsm_simulate_temp/`, `_wsm_diagnose_temp/`) and leaves
    its outputs there. It sits next to a single `.mo` file, or next to the top folder
    of a directory-form library, never inside the library. The launcher prints its
    path as `temp dir :`; `<temp-dir>` in the skills means that path. Tell the user,
    e.g.: "Working in temporary directory `_wsm_<mode>_temp/`. This will be deleted
    afterwards." Pass `--tempdir`
    to reuse one directory across models in a session.
    
    Clean up by removing the whole directory — use the user's shell:
    
    ```bash
    rm -rf "<temp-dir>"          # macOS / Linux
    # PowerShell: Remove-Item -Recurse -Force "<temp-dir>"
    ```
    
    ### Picking the model name
    
    - The user may provide a path to a `.mo` file, or you may already be working with
      one in context.
    - Extract the **model name**: the identifier after `model` on the first non-comment
      line, e.g. `model FooBar` → `FooBar`. The filename does not always match the
      model name — parse the actual `model`/`package` declaration.
    - For packages or nested models, use the **top-level** model name.
    - **Pick an instantiable model, not a package**, for any kernel call. A `package`
      cannot be validated or simulated ("Invalid instantiation … is a package") — use
      a nested model's full dotted name, e.g. `Package.Model`.
    - Pass an **absolute path** to `--model` (relative paths break as the working
      directory shifts between calls).
    - **A class that is already in a loaded library needs no `--model` at all** — give
      just the full dotted `--name` and the launcher takes it from MSL (or from a
      `--load-library` library). Use this for MSL examples rather than writing a
      wrapper model that extends one:
    
      ```bash
      python3 "<scripts-dir>/wsm_run.py" --mode diagnose \
        --name Modelica.Mechanics.MultiBody.Examples.Loops.EngineV6
      ```
    
      The temp dir then goes in the current directory. `--model` is still required
      for a class in the user's own file.
    
    ### Directory-form (multi-file) libraries
    
    A directory-form library stores one class per file with a `package.mo` at each
    level. You **cannot** validate such a class by handing the launcher only its own
    `.mo` file — the class's `within Lib;` clause needs the whole package loaded, and
    loading the single file alone fails with
    `Internal error: ... expandLibNode: Unknown library: Lib`. Instead point
    `--model` at the **library folder** (or its top `package.mo`, or any class file
    inside it) and pass the **full dotted class name** via `--name`:
    
    ```bash
    python3 "<scripts-dir>/wsm_run.py" --mode validate \
      --model "/abs/path/InvertedPendulum" \
      --name InvertedPendulum.Controller
    ```
    
    The launcher resolves any of those forms up to the library's root `package.mo`
    and loads the entire package (following `package.order`) before instantiating
    `--name`. It prints a `NOTE:` telling you which `package.mo` it loaded. Do **not**
    try to work around the unknown-library error by `--load`-ing individual files.
    
    ### Reading the JSON output
    
    The kernel writes `<mode>.out.json` into the temp dir. **It is a JSON *array* —
    take the first element**, then read:
    
    - **`status.flatten`**: `"Pass"` / `"Fail"` (the primary result for `validate`).
    - **`status.build`**: `"Pass"` / `"Fail"` — C++ compilation/linking (`simulate`).
    - **`status.result`**: simulation result status (`simulate`).
    - **`messages.errors`** / **`messages.warnings`** / **`messages.notifications`**:
      arrays (empty if none).
    - **`flat_model`** (`validate`) / **`simulation.resultFile`** (`simulate`): the
      flattened class / path to the `.mat`.
    
    See [`../scripts/README.md`](../scripts/README.md) (`wsm_run.py` section) for the full field reference.
    
    ### Checking graphic annotations
    
    A plain run does not evaluate the graphic annotations: `Icon`, `Diagram` and
    `Placement` are carried along untouched, so an error inside one cannot fail the
    run. Add `--graphics` to have them evaluated together with the model:
    
    ```bash
    python3 "<scripts-dir>/wsm_run.py" --mode validate --graphics \
      --model "<Model.mo>" --name "<Package>.<ModelName>" --timeout 90
    ```
    
    Errors then arrive through the usual `status.flatten` and `messages.errors`: a
    variable or component path that does not resolve, a misspelled shape
    (`Rectangel`) or field (`extend`), an array subscript out of bounds. This mode
    needs no C++ compiler, so it is the gate to run after editing annotations.
    
    The compiling modes (`--mode simulate`, `--mode diagnose`) additionally generate
    the model's diagram view, which evaluates the animated (`DynamicSelect`)
    expressions themselves. The launcher prints a `graphics :` line naming the
    generated view; if it was not generated it says so and exits non-zero, meaning an
    animated field could not be evaluated. It also exits non-zero, listing them, when
    an animated value falls back to its static value — typically an expression using a
    function the diagram does not support. Nothing else reports either.
    
    Evaluating the annotations is extra work for the frontend, so pass `--graphics`
    when the annotations are what you changed or are checking, not by default.
    
    Not every System Modeler version supports `--graphics`. On one that does not, the
    launcher drops it with a `NOTE:` and runs without it, so the graphic annotations are
    **not** checked; say so rather than reporting them as valid.
    
    ### MSL 4.x dialect
    
    This toolchain ships **MSL 4.x**. When authoring models, use the 4.x names — the
    3.2 names flatten with confusing "not found" errors:
    
    - units: `Modelica.Units.SI.*` (not `Modelica.SIunits.*`)
    - source frequency parameter: `f` (not `freqHz`), e.g. `SineVoltage(V=.., f=..)`
    - declare the dependency with the exact MSL version, e.g.
      `annotation(uses(Modelica(version="4.1.0")))`
    
    Run `python3 "<scripts-dir>/wsm_run.py" --mode info` to get the exact MSL
    version. `wsm_run.py` also warns on stderr if it spots a 3.2 name in the model.
    
    **When a flatten fails with `Element not found ... in Modelica...`**, the MSL
    component path is wrong (a misremembered name, not a missing install). Resolve
    the correct path with the **search-modelica-docs** skill — e.g. sine is
    `Modelica.Blocks.Sources.Sine` (not `Math.Sine`), difference is `Math.Feedback`
    (not `Math.Subtract`), and saturation is `Nonlinear.Limiter` (not
    `Nonlinear.Saturation`). **Do not** grep or walk the System Modeler install tree
    to hunt for the class.
    
    ### Using non-MSL libraries (Hydraulic, and other installed libraries)
    
    MSL is automatic (`--msl`). For **any other** library a model uses — Hydraulic, or
    anything the user installed from the Library Store — the launcher can find it for you.
    Two steps, no guessing at paths:
    
    1. **See what is installed** (bundled with System Modeler, user-installed archives, and
       any custom folders configured in Model Center):
    
       ```bash
       python3 "<scripts-dir>/wsm_run.py" --mode libraries
       # add --json for a machine-readable array; each row has name/version/source/package
       ```
    
       To get just one library's package path (e.g. for a manual `--load`):
       `--mode libraries --library Hydraulic` (add `--library-version 2.1` to pin a version).
    
    2. **Load it into a build** by name — add `--load-library <Name>` to a validate /
       simulate / diagnose run (repeatable; pin a version with `Name==Ver`):
    
       ```bash
       python3 "<scripts-dir>/wsm_run.py" --mode validate \
         --model "<path>/M.mo" --name M --load-library Hydraulic
       ```
    
       The launcher resolves the library (bundled → user-installed → Model-Center custom
       path, newest version wins) and `loadFile`s it before the model. A library usually
       pulls in MSL, so keep MSL on (auto, or `--msl yes`). Override a lookup with
       `$WSM_LIBRARY_<NAME>` (e.g. `WSM_LIBRARY_HYDRAULIC=/path/to/package.moe`), or fall
       back to an explicit `--load <path-to-package.mo|.moe>`.
    

Comments (0)

Sign in to join the conversation.

No comments yet.

Reviews (0)

No reviews yet.