hfss
Work with Ansys HFSS 3D through PyAEDT, AEDT, sim-plugin-hfss, or solver-native workflows. Use when the user asks an agent to inspect, build, edit, run, monitor, export, or debug HFSS 3D models.
Install
npx skills add https://github.com/svd-ai-lab/sim-cli/tree/main/plugins/hfss/src/sim_plugin_hfss/_skills/hfss
claude plugin marketplace add https://llmmart.ai/marketplace.json && claude plugin install svd-ai-lab-sim-cli@llmmart
git clone https://github.com/svd-ai-lab/sim-cli.git
The skills CLI installs just this skill, for any of its supported agents. Claude Code installs the whole svd-ai-lab/sim-cli collection as a plugin from our marketplace. Git is the plain clone.
Skill manifest
HFSS Skill
Use this skill for Ansys HFSS 3D work.
This plugin targets HFSS 3D through PyAEDT and AEDT. It does not yet cover HFSS 3D Layout, Maxwell, Icepak, Q3D, Circuit, or generic AEDT workflows.
sim-cli is a control and observability layer, not the only valid execution
path. Use sim check, sim connect, sim inspect, and bounded sim exec
snippets when they add discovery, session control, or structured evidence. Use
plain PyAEDT scripts, AEDT executables, vendor batch flows, or GUI operation
when those are the narrower reliable primitive. The evidence standard is the
same for every path.
Required Protocol
- Run an HFSS/AEDT availability probe before launch or solve.
- Use
sim check hfsswhensim-cliis available. - Acceptable alternatives: a PyAEDT import/version probe, AEDT executable path probe, Windows Registry/default-install probe, or environment variable probe.
- When probing nested Python packages such as
ansys.aedt.core, catchModuleNotFoundError; a missing top-levelansyspackage is evidence that the control package is absent, not a reason to launch AEDT for discovery. - Do not use
-helponansysedt.exe,ansysedtsv.exe, orhfss.exeas an availability probe. AEDT Student can open a modalElectronics Desktop Student Helpwindow and block automation when launched this way. - Missing
sim-cliis not evidence that AEDT/HFSS is missing.
- Use
- If no AEDT installation is found, stop and ask for an AEDT installation or
SIM_HFSS_AEDT_ROOTpath. Do not invent install paths. - Prefer no-GUI operation unless the user needs visual review or the workflow cannot expose the required state programmatically.
- Before setup, solve, export, or result interpretation, inspect the active project/design using the best available path:
sim inspect session.versions
sim inspect session.summary
sim inspect hfss.project.identity
sim inspect hfss.design.summary
sim inspect hfss.model.summary
sim inspect hfss.boundaries.summary
sim inspect hfss.setups.summary
Use release-specific API guidance only when session.versions reports
version_source: active_runtime. A newer AEDT installation detected on the
same host does not establish the version of the connected HFSS session.
If you are not using sim-cli, collect equivalent project, design, object,
boundary, port, setup, and sweep information through PyAEDT or AEDT APIs.
5. Run one bounded step at a time. After each mutation, inspect the changed
state and capture last.result, script output, or equivalent logs.
6. Treat process success as transport success only. Engineering acceptance must
come from HFSS results, exported data, convergence, S-parameters, fields,
far-field quantities, or another domain-specific criterion requested by the
user.
7. Keep failed evidence. If a solve/export fails, capture AEDT messages,
stdout/stderr, generated files, and the exact step that failed.
Common Workflows
Offline AEDT Project Probe
When the user only needs quick inventory or triage from a saved project and AEDT may not be installed, use the experimental offline inspector before launching AEDT:
python -m sim_plugin_hfss.aedt_inspect path/to/project.aedt
It can report best-effort project/design hints, variables, setup and sweep
names, port/boundary names, lock-file status, and .aedtresults sidecar
progress. It does not solve, read field data, extract mesh connectivity, or
provide authoritative geometry/boundary semantics. When accuracy matters,
validate the same file through PyAEDT/AEDT inspections.
Connect Through sim-cli
sim check hfss
sim connect --solver hfss --ui-mode no_gui
sim inspect session.summary
sim inspect hfss.project.identity
sim inspect hfss.design.summary
Use GUI mode only when the user needs to watch or interact with AEDT:
sim connect --solver hfss --ui-mode gui
Run a PyAEDT Script
Use this for a complete script that constructs or opens an HFSS project:
sim lint --solver hfss path/to/script.py
sim run --solver hfss path/to/script.py
Direct execution is also acceptable when it is clearer:
python path/to/script.py
In either case, preserve the AEDT project, logs, exported reports, and numeric acceptance results.
Execute a Bounded Snippet
After sim connect, snippets can use the live hfss object:
{
"project": hfss.project_name,
"design": hfss.design_name,
"setups": list(hfss.setup_names),
}
Prefer JSON-serializable results. Use sim inspect last.result after each
snippet.
Control-plane snippets are bounded by the HFSS driver by default. To tighten or disable that bound for a session, pass an explicit driver option:
sim connect --solver hfss --ui-mode no_gui --driver-option exec_timeout_s=60
Use short bounds for inspection, setup edits, and exporter snippets. Do not use
a fixed wall-clock timeout as the failure signal for real solves; solve-like
snippets such as analyze_setup(...) are not given the driver's default control
timeout unless you explicitly set exec_timeout_s. If a snippet returns
hung: true, treat the Python control handle as quarantined. Inspect
session.health for the tracked AEDT PID and liveness, drop only the quarantined
control session, then reattach the existing PID through the ordinary composable
commands before more HFSS work:
sim inspect session.health
sim disconnect
sim connect --solver hfss --ui-mode no_gui \
--driver-option new_desktop=false \
--driver-option aedt_process_id=<tracked-pid>
Do not interpret the control timeout as solver failure and do not start a duplicate solve while the preserved PID or solution artifacts still advance.
Export and Parse S-Parameters
When Touchstone export is available, export .sNp and parse it directly for
acceptance metrics. The connector exposes a best-effort helper in snippets:
touchstone_summary("path/to/result.s1p", target_frequencies_ghz=[5.8], threshold_db=-10)
Do not require scikit-rf just to compute minimum S-parameter, target-frequency
values, or threshold bandwidth.
Long Solves, Sweeps, and Multi-Physics Coupling
There is no dedicated resumable-sweep primitive and no automatic HFSS-to-Icepak coupling API, and none is planned. Drive both yourself with the generic primitives above instead of waiting for a purpose-built one:
- Multi-point sweeps: run one point at a time through bounded
run()/sim execcalls. Usesession.health/hfss.solution.progressbetween points to tell "still converging" from "actually hung." A stuck point does not require restarting the whole sweep — the AEDT project retains completed points, so reconnect and continue from the next point. - HFSS-to-Icepak coupling: there is no supported automatic EM-Loss link.
Read per-object/per-frequency loss from HFSS through the same
run(code)scripting used for inspection, then feed the computed value into Icepak's own (manual) heat-source assignment call. Seesim-cookbook/hfss/examples/cpw_thermoelectric_rf_power_sensor/for the staged recipe (RF baseline -> manual heat source -> loss-driven heat source).
Ask for a new driver primitive only when a generic gap actually blocks progress (for example, no timeout guard existed before v0.1.1) — not merely because a specific workflow would be more convenient with a dedicated shortcut.
Monitoring and Evidence
Use these inspections when available:
hfss.model.summaryfor object names, sheet/solid grouping, materials, and bounding boxes when PyAEDT exposes them.hfss.boundaries.summaryfor boundaries, excitations, ports, and associated objects when available.hfss.setups.summaryfor setup and sweep names/properties.hfss.messagesfor AEDT errors/warnings/info.hfss.solution.progressfor best-effort solved frequency progress from.aedtresultsfiles.session.healthfor PyAEDT/AEDT liveness, tracked owned AEDT PIDs, recent timeout cleanup, recent messages, and best-effort solve progress.
If an inspection is unavailable, report that honestly and use a solver-native fallback. Do not fabricate status.
Modeling Gotchas
- AEDT Student installs use the student launcher and may expose version strings
such as
2025.2SV. The connector patches PyAEDT 0.26.x startup handling for this case, but direct scripts may need the same care. - If an
Electronics Desktop Student Helpdialog appears during automation, close it, record the exact command, and remove-helpfrom the probe path. Use Registry/path/import checks for discovery, or run a real script invocation when the task needs AEDT execution. - For small antenna feeds between curved conductors, do not rely on
lumped_port(..., create_port_sheet=True)until the generated sheet has been visually or solver-message validated. HFSS can create a non-planar port sheet between round objects, which fails during port refinement. Prefer an explicit planar sheet plus an explicit two-point integration line. - Save the project before a real solve smoke, and capture
hfss.odesktop.GetMessages(...)immediately afteranalyze_setup(...)returns false. Reopening the project later can lose the most useful failure context. - For GUI evidence on Windows, inspect the screenshot after taking it. If a full-desktop capture is black, capture the AEDT window by handle instead of treating the file's existence as visual proof.
First-Version Limits
- Direct
.aedtand.aedtzsolving throughsim runis not validated yet. - Real HFSS release validation is opt-in and must be recorded separately from ordinary no-AEDT unit tests.
- Do not claim solver correctness from plugin unit tests alone.
Troubleshooting
- Driver not discovered: only when using
sim-cli, reinstall the plugin in the same environment as sim-cli and rerunsim check hfss. - AEDT not detected: set
SIM_HFSS_AEDT_ROOTto the directory containing an AEDT launcher, or rely on Registry/default discovery for common install layouts. A permanent globalPATHchange is optional, not required. - PyAEDT import error: install
pyaedt>=0.26.3,<1in the active environment. - Script not detected: make sure it constructs HFSS through PyAEDT, for example
from ansys.aedt.core.hfss import Hfssfollowed byHfss(...).
Files (sim-cli)
-
SKILL.md 10.4 KB
--- name: hfss description: "Work with Ansys HFSS 3D through PyAEDT, AEDT, sim-plugin-hfss, or solver-native workflows. Use when the user asks an agent to inspect, build, edit, run, monitor, export, or debug HFSS 3D models." --- # HFSS Skill Use this skill for Ansys HFSS 3D work. This plugin targets HFSS 3D through PyAEDT and AEDT. It does not yet cover HFSS 3D Layout, Maxwell, Icepak, Q3D, Circuit, or generic AEDT workflows. `sim-cli` is a control and observability layer, not the only valid execution path. Use `sim check`, `sim connect`, `sim inspect`, and bounded `sim exec` snippets when they add discovery, session control, or structured evidence. Use plain PyAEDT scripts, AEDT executables, vendor batch flows, or GUI operation when those are the narrower reliable primitive. The evidence standard is the same for every path. ## Required Protocol 1. Run an HFSS/AEDT availability probe before launch or solve. - Use `sim check hfss` when `sim-cli` is available. - Acceptable alternatives: a PyAEDT import/version probe, AEDT executable path probe, Windows Registry/default-install probe, or environment variable probe. - When probing nested Python packages such as `ansys.aedt.core`, catch `ModuleNotFoundError`; a missing top-level `ansys` package is evidence that the control package is absent, not a reason to launch AEDT for discovery. - Do not use `-help` on `ansysedt.exe`, `ansysedtsv.exe`, or `hfss.exe` as an availability probe. AEDT Student can open a modal `Electronics Desktop Student Help` window and block automation when launched this way. - Missing `sim-cli` is not evidence that AEDT/HFSS is missing. 2. If no AEDT installation is found, stop and ask for an AEDT installation or `SIM_HFSS_AEDT_ROOT` path. Do not invent install paths. 3. Prefer no-GUI operation unless the user needs visual review or the workflow cannot expose the required state programmatically. 4. Before setup, solve, export, or result interpretation, inspect the active project/design using the best available path: ```bash sim inspect session.versions sim inspect session.summary sim inspect hfss.project.identity sim inspect hfss.design.summary sim inspect hfss.model.summary sim inspect hfss.boundaries.summary sim inspect hfss.setups.summary ``` Use release-specific API guidance only when `session.versions` reports `version_source: active_runtime`. A newer AEDT installation detected on the same host does not establish the version of the connected HFSS session. If you are not using `sim-cli`, collect equivalent project, design, object, boundary, port, setup, and sweep information through PyAEDT or AEDT APIs. 5. Run one bounded step at a time. After each mutation, inspect the changed state and capture `last.result`, script output, or equivalent logs. 6. Treat process success as transport success only. Engineering acceptance must come from HFSS results, exported data, convergence, S-parameters, fields, far-field quantities, or another domain-specific criterion requested by the user. 7. Keep failed evidence. If a solve/export fails, capture AEDT messages, stdout/stderr, generated files, and the exact step that failed. ## Common Workflows ### Offline AEDT Project Probe When the user only needs quick inventory or triage from a saved project and AEDT may not be installed, use the experimental offline inspector before launching AEDT: ```bash python -m sim_plugin_hfss.aedt_inspect path/to/project.aedt ``` It can report best-effort project/design hints, variables, setup and sweep names, port/boundary names, lock-file status, and `.aedtresults` sidecar progress. It does not solve, read field data, extract mesh connectivity, or provide authoritative geometry/boundary semantics. When accuracy matters, validate the same file through PyAEDT/AEDT inspections. ### Connect Through sim-cli ```bash sim check hfss sim connect --solver hfss --ui-mode no_gui sim inspect session.summary sim inspect hfss.project.identity sim inspect hfss.design.summary ``` Use GUI mode only when the user needs to watch or interact with AEDT: ```bash sim connect --solver hfss --ui-mode gui ``` ### Run a PyAEDT Script Use this for a complete script that constructs or opens an HFSS project: ```bash sim lint --solver hfss path/to/script.py sim run --solver hfss path/to/script.py ``` Direct execution is also acceptable when it is clearer: ```bash python path/to/script.py ``` In either case, preserve the AEDT project, logs, exported reports, and numeric acceptance results. ### Execute a Bounded Snippet After `sim connect`, snippets can use the live `hfss` object: ```python { "project": hfss.project_name, "design": hfss.design_name, "setups": list(hfss.setup_names), } ``` Prefer JSON-serializable results. Use `sim inspect last.result` after each snippet. Control-plane snippets are bounded by the HFSS driver by default. To tighten or disable that bound for a session, pass an explicit driver option: ```bash sim connect --solver hfss --ui-mode no_gui --driver-option exec_timeout_s=60 ``` Use short bounds for inspection, setup edits, and exporter snippets. Do not use a fixed wall-clock timeout as the failure signal for real solves; solve-like snippets such as `analyze_setup(...)` are not given the driver's default control timeout unless you explicitly set `exec_timeout_s`. If a snippet returns `hung: true`, treat the Python control handle as quarantined. Inspect `session.health` for the tracked AEDT PID and liveness, drop only the quarantined control session, then reattach the existing PID through the ordinary composable commands before more HFSS work: ```bash sim inspect session.health sim disconnect sim connect --solver hfss --ui-mode no_gui \ --driver-option new_desktop=false \ --driver-option aedt_process_id=<tracked-pid> ``` Do not interpret the control timeout as solver failure and do not start a duplicate solve while the preserved PID or solution artifacts still advance. ### Export and Parse S-Parameters When Touchstone export is available, export `.sNp` and parse it directly for acceptance metrics. The connector exposes a best-effort helper in snippets: ```python touchstone_summary("path/to/result.s1p", target_frequencies_ghz=[5.8], threshold_db=-10) ``` Do not require `scikit-rf` just to compute minimum S-parameter, target-frequency values, or threshold bandwidth. ### Long Solves, Sweeps, and Multi-Physics Coupling There is no dedicated resumable-sweep primitive and no automatic HFSS-to-Icepak coupling API, and none is planned. Drive both yourself with the generic primitives above instead of waiting for a purpose-built one: - **Multi-point sweeps**: run one point at a time through bounded `run()` / `sim exec` calls. Use `session.health` / `hfss.solution.progress` between points to tell "still converging" from "actually hung." A stuck point does not require restarting the whole sweep — the AEDT project retains completed points, so reconnect and continue from the next point. - **HFSS-to-Icepak coupling**: there is no supported automatic EM-Loss link. Read per-object/per-frequency loss from HFSS through the same `run(code)` scripting used for inspection, then feed the computed value into Icepak's own (manual) heat-source assignment call. See `sim-cookbook/hfss/examples/cpw_thermoelectric_rf_power_sensor/` for the staged recipe (RF baseline -> manual heat source -> loss-driven heat source). Ask for a new driver primitive only when a generic gap actually blocks progress (for example, no timeout guard existed before v0.1.1) — not merely because a specific workflow would be more convenient with a dedicated shortcut. ## Monitoring and Evidence Use these inspections when available: - `hfss.model.summary` for object names, sheet/solid grouping, materials, and bounding boxes when PyAEDT exposes them. - `hfss.boundaries.summary` for boundaries, excitations, ports, and associated objects when available. - `hfss.setups.summary` for setup and sweep names/properties. - `hfss.messages` for AEDT errors/warnings/info. - `hfss.solution.progress` for best-effort solved frequency progress from `.aedtresults` files. - `session.health` for PyAEDT/AEDT liveness, tracked owned AEDT PIDs, recent timeout cleanup, recent messages, and best-effort solve progress. If an inspection is unavailable, report that honestly and use a solver-native fallback. Do not fabricate status. ## Modeling Gotchas - AEDT Student installs use the student launcher and may expose version strings such as `2025.2SV`. The connector patches PyAEDT 0.26.x startup handling for this case, but direct scripts may need the same care. - If an `Electronics Desktop Student Help` dialog appears during automation, close it, record the exact command, and remove `-help` from the probe path. Use Registry/path/import checks for discovery, or run a real script invocation when the task needs AEDT execution. - For small antenna feeds between curved conductors, do not rely on `lumped_port(..., create_port_sheet=True)` until the generated sheet has been visually or solver-message validated. HFSS can create a non-planar port sheet between round objects, which fails during port refinement. Prefer an explicit planar sheet plus an explicit two-point integration line. - Save the project before a real solve smoke, and capture `hfss.odesktop.GetMessages(...)` immediately after `analyze_setup(...)` returns false. Reopening the project later can lose the most useful failure context. - For GUI evidence on Windows, inspect the screenshot after taking it. If a full-desktop capture is black, capture the AEDT window by handle instead of treating the file's existence as visual proof. ## First-Version Limits - Direct `.aedt` and `.aedtz` solving through `sim run` is not validated yet. - Real HFSS release validation is opt-in and must be recorded separately from ordinary no-AEDT unit tests. - Do not claim solver correctness from plugin unit tests alone. ## Troubleshooting - Driver not discovered: only when using `sim-cli`, reinstall the plugin in the same environment as sim-cli and rerun `sim check hfss`. - AEDT not detected: set `SIM_HFSS_AEDT_ROOT` to the directory containing an AEDT launcher, or rely on Registry/default discovery for common install layouts. A permanent global `PATH` change is optional, not required. - PyAEDT import error: install `pyaedt>=0.26.3,<1` in the active environment. - Script not detected: make sure it constructs HFSS through PyAEDT, for example `from ansys.aedt.core.hfss import Hfss` followed by `Hfss(...)`.
Comments (0)
Sign in to join the conversation.
Reviews (0)
No reviews yet.
No comments yet.