annotate-modelica-plots
Add standardized Modelica result-plot annotations (Documentation(figures={Figure/Plot/Curve/Axis})) to a .mo model so simulation plots are stored in the model itself and reopen in Wolfram System Modeler. Use this skill whenever the user wants to store, embed, or save result plots
Install
npx skills add https://github.com/WolframResearch/system-modeler-ai-toolkit/tree/main/annotate-modelica-plots
claude plugin marketplace add https://llmmart.ai/marketplace.json && claude plugin install wolframresearch-system-modeler-ai-toolkit@llmmart
git clone https://github.com/WolframResearch/system-modeler-ai-toolkit.git
The skills CLI installs just this skill, for any of its supported agents. Claude Code installs the whole wolframresearch/system-modeler-ai-toolkit collection as a plugin from our marketplace. Git is the plain clone.
Skill manifest
Annotate Modelica Plots
This skill writes the spec-standard result-plot annotation into a Modelica .mo file so a
model carries its own simulation plots:
annotation(Documentation(figures = {
Figure(identifier = "response", title = "Mass response", preferred = true,
plots = {
Plot(title = "Position and velocity",
curves = {Curve(x = time, y = s, legend = "position"),
Curve(x = time, y = v, legend = "velocity")},
x = Axis(label = "time"), y = Axis(label = "states", unit = ""))})}));
It is a self-contained source transform: Claude assembles a figures spec (JSON) — from the user's request, or from variables discovered by simulating — and the Python engine renders it to valid Modelica and splices it into the class annotation. The engine is pure Python (standard library only); WSMKernelX is used only afterwards as a validation gate.
Wolfram System Modeler renders this standard annotation natively from the stored figure, picking up
the Plot.title, Axis.label, and per-curve legend. No vendor-specific annotation is needed.
It can also add System Modeler plot markers (__Wolfram_markers): labelled lines drawn on the
stored plot. A vertical marker at a time makes the plot's Measurements panel list every curve's
value at that time; a horizontal marker at a level lists every time a curve crosses it. See
step 3c.
It is idempotent: a class that already has figures = is skipped unless you pass --force
(which strips the old figures assignment and regenerates). By default it prints a dry-run diff;
nothing is written until --write.
--forceis destructive — ask the user first. It deletes the class's existingfiguresblock before regenerating, so any hand-written or previously curated plot definitions there are lost (a user may have tuned those by hand). Don't pass--forceon a class that already carries figures without first confirming with the user that discarding them is intended. Review the dry-run diff (no--write) to see exactly what would be removed.
The figures spec (JSON)
Shaped after the spec records (MLS annotations.tex §figure-plot-properties). Only fields you set
are emitted:
{
"figures": [
{
"title": "Mass response", "identifier": "response", "preferred": true,
"caption": "Damped oscillation of %[position](variable:s).",
"plots": [
{
"identifier": "states",
"title": "Position and velocity",
"x": {"label": "time"},
"y": {"label": "states", "unit": "", "scale": "Linear"},
"curves": [
{"x": "time", "y": "s", "legend": "position"},
{"x": "time", "y": "v", "legend": "velocity"}
]
}
],
"markers": [
{"identifier": "first_min", "x": 1.0, "xUnit": "s", "label": "first minimum",
"plots": ["states"], "labelPosition": {"yOffsetCanvas": 0.9, "verticalAlignment": "Top"}},
{"identifier": "rest", "y": 0.0, "yUnit": "m", "label": "rest position"}
]
}
]
}
Marker fields (a position is required, the rest is optional):
xory—xis a vertical line at a position on the x axis,ya horizontal line at a level. Never both: System Modeler does not draw such a marker. On a time-based plotxis a time ("xUnit": "s"); on an X vs. Y plot it is a value of the x variable, in its unit (e.g."x": 0, "xUnit": "mm") — a time there lands at that value of the x variable instead.yUnit— the unit of aylevel. Always set it, preferably to the unit the plot's y axis shows; without it the number is read in the axis unit, whatever that is.label— text drawn on the line.%{var}shows the variable's final value in its display unit.plots— plot identifiers or 0-based indices that show the marker; default is every plot of the figure. Restrict aymarker to the plots whose y axis it belongs to.labelPosition— where the label sits along the line, from 0 to 1:yOffsetCanvasfor a vertical marker (0 = bottom),xOffsetCanvasfor a horizontal one (0 = left). PlusverticalAlignment(Top|Center|Bottom, defaultBottom) andhorizontalAlignment(Left|Center|Right, defaultLeft).yAxis—"right"for a level on the right y axis; default"left".identifier— unique within the figure; defaults tom1,m2, ...
Rules the engine enforces (from the spec):
Curve.x/Curve.ymust be result-references: a scalar variable (s,mass.v),time, order(v[, n])— not arbitrary expressions. A bad reference is a hard error.xdefaults to"time"; set it to a variable for an X vs. Y plot (e.g.{"x": "s", "y": "v"}for a phase portrait).Figure.identifiermust be unique in the spec;Plot.identifierunique within its figure.- A marker has exactly one numeric position, a unique identifier within its figure, and
plotsentries naming existing plots. - Axis
scaleis"Linear"(default),"Log", or{"Log": 10}to set the base. %{var}variable replacements and%[text](variable:ref)caption links are passed through; the engine does not invent them.
To target a specific class in a multi-model file, either pass --class <Name>, or use a mapping
spec {"Oscillator": {"figures": [...]}, "Plain": {"figures": [...]}}.
Running the annotator
The annotator lives in the PlotAnnotate/ package next to this file. Run it as a module from
this skill's directory so the package is importable:
cd "<this-skill-dir>"
python3 -m PlotAnnotate.main --file "<path-to-Model.mo>" --analyze
Use python instead of python3 on Windows if that's what's on PATH. Only --file (and --spec,
--vars-file) must be absolute or correctly-relative paths.
Cross-platform launcher (for simulate / validate steps)
The simulate/validate steps below call the shared
scripts/wsm_run.pyandscripts/plot_mat.py. Read the shared-conventions appendix at the end of this file (launcher resolution, shell rules, temp dir, JSON-array output, MSL 4.x notes) before those steps. In a normal install the launcher is../scripts/wsm_run.py(<scripts-dir>is the sharedscripts/folder); if that path doesn't exist, see Appendix → Locating the launcher.
Workflow
1. Identify the model file and target class
The user gives a .mo path. Pick a concrete instantiable model for any kernel step
(Package.Model, not the package) — see
Appendix → Picking the model name.
2. Analyze — see classes and existing figure status
python3 -m PlotAnnotate.main --file "<Model.mo>" --analyze
Lists every class, flagging has Documentation / HAS figures. Present this and confirm scope.
3. Choose what to plot
Pick curves that reveal emergent / non-obvious behavior — a dynamic response, a comparison, a phase shift, a limit case. Skip tautological curves that just re-trace a known input signal (if you'd see the same shape by plotting the input alone, it teaches nothing).
Curves default to x = time, but Curve.x can be any result variable, giving an X vs. Y
plot. Reach for one when the relationship between two variables is the story: a phase portrait
of an oscillator (limit cycles show as closed loops), a hysteresis loop, a transfer or force-
displacement characteristic. Put an X vs. Y curve in its own Plot (not mixed with time-based
curves — they'd share the x axis) and label both axes.
Mode A — user-specified. The user already knows the curves. Build the spec JSON directly from their request and skip to step 4.
Mode B — simulate-and-suggest. When the user doesn't name variables, discover them:
# simulate to produce a .mat (and, beside it, a .sim init file with the same stem)
python3 "<scripts-dir>/wsm_run.py" --mode simulate --model "<Model.mo>" --name "<Package.Model>" --timeout 180
# enumerate result variables (write working files next to the model, not into the skill dir)
python3 "<scripts-dir>/plot_mat.py" "<temp-dir>/<result>.mat" --list > "<Model-dir>/vars.txt"
# get a starting spec (filters time/der/aux; one plot, x=time). Pass the .sim so protected
# variables are dropped — they are stored in the .mat but render blank in a stored figure.
python3 -m PlotAnnotate.main --file "<Model.mo>" --vars-file "<Model-dir>/vars.txt" \
--sim-file "<temp-dir>/<result>.sim" --suggest --max-curves 8 > "<Model-dir>/figs.json"
<result>.mat is the file named by simulation.resultFile in simulate.out.json; the .sim
file sits next to it with the same stem (swap the .mat extension for .sim).
Passing --sim-file is what stops protected variables from being suggested — without it, a
protected variable in the result is offered as a curve and then renders blank in System Modeler.
The suggestion is a starting point — refine figs.json: drop parameters/noise, split into
multiple plots by physical quantity, set titles/legends/axis units. Passing --vars-file to the
--annotate step also warns when a curve references a variable absent from the result; passing
--sim-file there additionally warns when a curve references a protected variable.
3b. Title, caption, and reference alignment
Every figure should be self-identifying and self-explaining:
- Title — name the quantity shown, not "Plot 1" (e.g.
"Refrigerant pressure"). The title is how the user finds the plot in the model's figure list, so make it scannable. - Caption — set a one-line
captionon everyFiguresaying what it shows and what to look for (e.g. "Pressure rises with the accumulation after the step"). It renders beneath the plot in System Modeler. Use%[label](variable:ref)to link a variable inside the caption. - Default — mark exactly one figure
preferred = trueso it opens by default. - Reference alignment — if the model implements a published reference (a paper, app note,
textbook) and that reference numbers its figures, name the model's figures to match it
(
"Fig. 6 - Stored refrigerant mass") and state the correspondence in the caption ("compare Fig. 6 of
3c. Markers — mark a time or a level (optional)
Add markers when the user asks to mark, measure or label something on a plot, or when a caption makes a claim ("settles in 13 s") that a marker makes visible. Keep them few: two or three that support the caption beat a marker on every extremum.
If the user gives the numbers ("a line at 3 bar", "mark t = 2.5 s"), write the markers into the
spec directly. Otherwise simulate (as in Mode B) and let mat_features.py find the positions and
add the markers to a figure of the spec. Each feature is VAR:KIND[:ARG]:
| Feature | Marker |
|---|---|
s:max, s:min |
vertical line at the time of the extremum |
s:at:2.5 |
vertical line at t = 2.5 s |
s:settle:0.02 |
vertical line at the settling time: within 2 % of the step of its final value, or of its largest deviation from it when s returns to where it started; fails if s is still outside that band in the last 10 % of the run |
s:cross:0.5 |
horizontal line at the level 0.5, in the unit the marker is written in |
s:final, s:initial |
horizontal line at the final / initial value |
python3 "<scripts-dir>/mat_features.py" "<temp-dir>/<result>.mat" s:min s:settle:0.02 \
--spec "<Model-dir>/figs.json" --figure response --plots states
Horizontal lines are written in the unit the plot's y axis shows (the plot's Axis.unit, else the
variable's displayUnit); pass --unit bar to choose it, which also sets the unit of a cross
level. Run it once per group of plots that share a y axis. Without --spec it prints the markers
as JSON; for a mapping spec, name the class with --class. Re-running a feature replaces its marker. Labels carry the measured value; the final
label uses %{var}, so it stays correct after the model changes.
4. Preview — dry-run diff
python3 -m PlotAnnotate.main --file "<Model.mo>" --class "<Model>" --spec "<Model-dir>/figs.json" --annotate
Shows the unified diff without writing. --vars-file "<Model-dir>/vars.txt" adds membership warnings,
and --sim-file "<temp-dir>/<result>.sim" warns on any curve that references a
protected variable. --force regenerates over an existing figures block.
5. Apply — write in place
python3 -m PlotAnnotate.main --file "<Model.mo>" --class "<Model>" --spec "<Model-dir>/figs.json" --annotate --write
Re-running without --force is a no-op for already-annotated classes (idempotent).
6. Validate — confirm the model still flattens (validate-modelica gate)
Annotations must not change the flatten result, and System Modeler must accept every part of the
figures. --figures has the kernel parse them as System Modeler does when it opens the plots.
python3 "<scripts-dir>/wsm_run.py" --mode validate --figures --model "<Model.mo>" --name "<Package.Model>" --timeout 90
Parse <temp-dir>/validate.out.json (a JSON array — take [0]; field reference:
Appendix → Reading the JSON output) and check
status.flatten == "Pass". If it passed before annotating but fails after, that's a bug in the
annotation, not the user's model — report it. The launcher also prints a figures : line and
exits non-zero, listing each part System Modeler would ignore (a malformed curve, an unknown
attribute, a misspelled MarkerPosition); fix those in the spec and regenerate rather than
editing the figures block by hand. Then remove the temp dir.
Notes and edge cases
- Pick an instantiable model for the kernel steps, not the package — use a nested model's full dotted name. See Appendix → Picking the model name.
figuresis inherited. A class's figures = its own plus those from base classes. KeepFigure.identifiers unique across that whole collection (the engine checks within one spec; it can't see base-class figures, so choose distinct identifiers when extending).- Result-references only. To plot a derived quantity, add a variable for it in the model and
reference that —
Curve.ycannot be an expression likes + v. - No protected variables in curves. System Modeler stores protected variables in the result
.mat(soplot_mat.py --listshows them), but a stored figure resolves curves against the public result tree only — a curve on a protected variable renders blank, and the model still flattens, so the validate gate won't catch it. The.simfile beside the.matmarks them (protected="true"); pass it as--sim-fileto--suggest/--annotateso they are dropped and flagged. If you must show a protected quantity, expose it through a public variable in the model. - X vs. Y (parametric) curves are supported.
Curve.xdefaults totime, but any result-reference works (Curve(x = x, y = y)), and System Modeler renders the variable-vs-variable curve natively. Same rules asy: a result-reference (no expressions), and a protected variable renders blank on either axis. Don't mix time-based and X-vs-Y curves in onePlot— all curves share the plot's x axis (the engine warns on this); use separate plots. Label both axes, since the default "time" x-label no longer applies. A vertical marker on an X vs. Y plot sits at a value of the x variable, not at a time, so restrictmat_features.py's time features (max,min,at,settle) to time-based plots with--plots(it refuses otherwise). - Marker positions are numbers. A marker does not move when parameters change; after
re-tuning, re-simulate, re-run
mat_features.pyand regenerate with--force. - Units. A non-empty
Axis.unitmust be compatible with the plotted variable's unit, or the model won't flatten; leaveunit = ""to let the tool choose per-curve units. - Idempotency / regen. Default runs never duplicate a
figuresblock; use--forceto regenerate after editing the spec — but it discards the existing figures (hand-written included), so confirm with the user first (see the caution near the top). - MSL dialect (this toolchain ships MSL 4.x). Annotations don't affect flattening, but if the model uses 3.2 names it fails the gate for unrelated reasons — see Appendix → MSL 4.x dialect.
Appendix: shared conventions for the Modelica skills
Shared by every Modelica skill that drives WSMKernelX through the bundled launcher; inlined here at release time. For the CLI/option reference, environment variables (
WSM_HOME,WSM_VSDEVCMD), install discovery, and the analysis scripts, see../scripts/README.md.
These are conventions, not a workflow. Knowing how to call the tools is not the same as knowing which to call, in what order, and how to tell a good answer from a plausible one — that lives in the skills, one per job. Invoke the one that owns the step you are on, including when it is not the one you started from: a job that begins in one skill routinely runs into something another one owns, and the whole toolkit is available the entire time.
| What you run into | Skill |
|---|---|
| About to write or restructure a model or library — including one you decided to build yourself | modelica-model-architecture first |
A .mo you just wrote or edited; a structural error |
validate-modelica |
| You need results | simulate-modelica (simulate-and-plot-modelica to plot them too) |
| A run that must go in real time, take input changes while it runs, or be driven from another program | simulate-modelica-realtime |
| It validates but will not build; it runs far too slowly; it gives an answer you cannot account for; you need its states, equations or blocks | diagnose-modelica |
The launcher reports a compiler failure — an internal error, generated code that does not compile, a simulator internal error or a kernel crash |
minimize-modelica-bug |
| A Modelica language or MSL question you would otherwise answer from memory | search-modelica-docs |
| Sweeps, limit checks, calibration, custom result analysis | wolfram-language-modelica |
| No icons, or no diagram layout | annotate-modelica-graphics |
| Plots that should live in the model and reopen with it | annotate-modelica-plots |
| Interactive sliders in Simulation Center's Explore view | annotate-control-panel |
| 3D MultiBody animation | annotate-modelica-animation |
| A hydraulic circuit | create-hydraulic-model |
Locating the launcher
<scripts-dir> (used throughout the skills) is the shared scripts/ folder.
Some installs symlink the skill directories without it, so resolve it in this
order and use the first that exists:
$WSM_SKILLS_SCRIPTS(bash) or$env:WSM_SKILLS_SCRIPTS(PowerShell), if set.../scriptsrelative to the skill directory — in a normal install../scripts/wsm_run.pyalready exists, so use that path directly; do not run a shell probe to "resolve" it.- The folder you cloned or unzipped the skills from, e.g.
.../system-modeler-ai-toolkit/scripts. - Last resort, search the home directory:
- PowerShell:
Get-ChildItem $HOME -Recurse -Filter wsm_run.py -ErrorAction SilentlyContinue | Select-Object -First 1 - bash/zsh:
find ~ -name wsm_run.py -path '*scripts*' 2>/dev/null | head -1
- PowerShell:
If only #4 finds it, the install is missing the scripts/ link — tell the user
to run install.sh (or install.ps1) from the repo, which links scripts/ too.
Shell and Python
On Windows, use PowerShell. The Git-Bash/cygwin layer may be broken (even
ls/find can be absent, giving a misleading "exit 127 / command not found").
Run wsm_run.py with python (not python3); those calls are single-line and
shell-agnostic. For cleanup use Remove-Item -Recurse -Force, not rm -rf.
On macOS/Linux any POSIX shell is fine and python3 is the usual name.
For your own analysis, borrow the scripts' interpreter. Whatever python3
you get is unlikely to have numpy or scipy, and installing into it is both rude
and often blocked. The analysis scripts run under a managed virtualenv with
numpy, scipy, matplotlib and DyMat; python3 <scripts-dir>/bootstrap_env.py
makes sure they are installed there and prints its interpreter path. Use that
interpreter for ad-hoc post-processing rather than discovering package by
package what the system one lacks.
Line endings in .mo files
Modelica models are written on Windows, macOS and Linux alike, so a .mo file
may use CRLF or LF. Neither is the "right" one. Match whatever the file
already has, and never leave a file with a mix of both — a mixed file shows up
as a whole-file diff the moment anything rewrites it, burying the real change.
When you edit a .mo yourself with the Write/Edit tools (rather than through one
of the annotator scripts), those tools write back exactly the text you give them,
so an edit in the other style silently mixes the file. Check before, and check
again after:
python3 "<scripts-dir>/mo_edit.py" --eol "<Model.mo>"
It prints LF, CRLF, MIXED (crlf=N lf=M) or NONE, and exits non-zero on
MIXED. If an edit did change the endings, put them back — this rewrites the
whole file to one ending, so it also repairs a mixed one:
python3 "<scripts-dir>/mo_edit.py" --set-eol auto "<Model.mo>" # or: lf, or crlf
A mixed file follows its library, not itself. If the file you are editing is
mixed while the rest of the library is consistent, do not settle it on whichever
ending dominates inside that file — the mixing is damage, so the file is not
evidence about itself, and its majority leaves you with the one odd file out.
Use the library's ending. auto does this for you, and reports which rule it
applied.
Creating a new .mo: same rule — match the sibling .mo files in the same
directory or library (--eol accepts several paths at once), so one library does
not end up half CRLF and half LF. Use LF only when there is nothing to match.
The annotator scripts' --write paths already preserve the file's endings and
warn about a mixed input, so no manual step is needed around those.
Let the launcher own .mos/.bat and paths
Do not hand-write .mos scripts, .bat files, or hardcode install/compiler
paths. The bundled scripts/wsm_run.py handles every OS difference — it finds
the System Modeler install and kernel binary (macOS / Windows / Linux), finds and
loads the right MSL files, generates the .mos, and runs the kernel with a
working compiler environment per platform (system clang/gcc on macOS/Linux; the
Visual Studio dev environment via VsDevCmd.bat on Windows).
See ../scripts/README.md for WSM_HOME, the Windows compiler prerequisites,
and the full option table.
When the install or compiler isn't found
The launcher searches each OS's standard install locations. If it prints
ERROR: Could not locate a Wolfram System Modeler installation, the install
is in a non-standard place — ask the user for it and re-run with
--wsm-home "<path>" (or have them set WSM_HOME).
Building and simulating also need a C++ toolchain:
- Windows: Visual Studio Build Tools. The launcher locates
VsDevCmd.batitself; if it reports the compiler environment is missing, pass--vsdevcmd "<path-to-VsDevCmd.bat>"(or setWSM_VSDEVCMD) and make sure Build Tools are installed. - macOS: the Xcode command-line tools (
xcode-select --install). - Linux: gcc/g++.
Run python3 "<scripts-dir>/wsm_run.py" --mode info to see what the launcher
discovered.
Checking the setup
When the user asks whether the machine is ready for these skills, run
python3 <scripts-dir>/wsm_run.py --mode info and report what it prints: the
System Modeler installation it found and, on Windows, the compiler environment.
If InstallationGuide.md sits next to the scripts/ folder, as it does when
the skills are installed as a plugin, it lists what each skill needs: follow its
Steps 2, 4 and 5, and do not run the installer.
Temporary directories
The launcher works in a _wsm_<mode>_temp/ directory
(_wsm_validate_temp/, _wsm_simulate_temp/, _wsm_diagnose_temp/) and leaves
its outputs there. It sits next to a single .mo file, or next to the top folder
of a directory-form library, never inside the library. The launcher prints its
path as temp dir :; <temp-dir> in the skills means that path. Tell the user,
e.g.: "Working in temporary directory _wsm_<mode>_temp/. This will be deleted
afterwards." Pass --tempdir
to reuse one directory across models in a session.
Clean up by removing the whole directory — use the user's shell:
rm -rf "<temp-dir>" # macOS / Linux
# PowerShell: Remove-Item -Recurse -Force "<temp-dir>"
Picking the model name
The user may provide a path to a
.mofile, or you may already be working with one in context.Extract the model name: the identifier after
modelon the first non-comment line, e.g.model FooBar→FooBar. The filename does not always match the model name — parse the actualmodel/packagedeclaration.For packages or nested models, use the top-level model name.
Pick an instantiable model, not a package, for any kernel call. A
packagecannot be validated or simulated ("Invalid instantiation … is a package") — use a nested model's full dotted name, e.g.Package.Model.Pass an absolute path to
--model(relative paths break as the working directory shifts between calls).A class that is already in a loaded library needs no
--modelat all — give just the full dotted--nameand the launcher takes it from MSL (or from a--load-librarylibrary). Use this for MSL examples rather than writing a wrapper model that extends one:python3 "<scripts-dir>/wsm_run.py" --mode diagnose \ --name Modelica.Mechanics.MultiBody.Examples.Loops.EngineV6The temp dir then goes in the current directory.
--modelis still required for a class in the user's own file.
Directory-form (multi-file) libraries
A directory-form library stores one class per file with a package.mo at each
level. You cannot validate such a class by handing the launcher only its own
.mo file — the class's within Lib; clause needs the whole package loaded, and
loading the single file alone fails with
Internal error: ... expandLibNode: Unknown library: Lib. Instead point
--model at the library folder (or its top package.mo, or any class file
inside it) and pass the full dotted class name via --name:
python3 "<scripts-dir>/wsm_run.py" --mode validate \
--model "/abs/path/InvertedPendulum" \
--name InvertedPendulum.Controller
The launcher resolves any of those forms up to the library's root package.mo
and loads the entire package (following package.order) before instantiating
--name. It prints a NOTE: telling you which package.mo it loaded. Do not
try to work around the unknown-library error by --load-ing individual files.
Reading the JSON output
The kernel writes <mode>.out.json into the temp dir. It is a JSON array —
take the first element, then read:
status.flatten:"Pass"/"Fail"(the primary result forvalidate).status.build:"Pass"/"Fail"— C++ compilation/linking (simulate).status.result: simulation result status (simulate).messages.errors/messages.warnings/messages.notifications: arrays (empty if none).flat_model(validate) /simulation.resultFile(simulate): the flattened class / path to the.mat.
See ../scripts/README.md (wsm_run.py section) for the full field reference.
Checking graphic annotations
A plain run does not evaluate the graphic annotations: Icon, Diagram and
Placement are carried along untouched, so an error inside one cannot fail the
run. Add --graphics to have them evaluated together with the model:
python3 "<scripts-dir>/wsm_run.py" --mode validate --graphics \
--model "<Model.mo>" --name "<Package>.<ModelName>" --timeout 90
Errors then arrive through the usual status.flatten and messages.errors: a
variable or component path that does not resolve, a misspelled shape
(Rectangel) or field (extend), an array subscript out of bounds. This mode
needs no C++ compiler, so it is the gate to run after editing annotations.
The compiling modes (--mode simulate, --mode diagnose) additionally generate
the model's diagram view, which evaluates the animated (DynamicSelect)
expressions themselves. The launcher prints a graphics : line naming the
generated view; if it was not generated it says so and exits non-zero, meaning an
animated field could not be evaluated. It also exits non-zero, listing them, when
an animated value falls back to its static value — typically an expression using a
function the diagram does not support. Nothing else reports either.
Evaluating the annotations is extra work for the frontend, so pass --graphics
when the annotations are what you changed or are checking, not by default.
Not every System Modeler version supports --graphics. On one that does not, the
launcher drops it with a NOTE: and runs without it, so the graphic annotations are
not checked; say so rather than reporting them as valid.
MSL 4.x dialect
This toolchain ships MSL 4.x. When authoring models, use the 4.x names — the 3.2 names flatten with confusing "not found" errors:
- units:
Modelica.Units.SI.*(notModelica.SIunits.*) - source frequency parameter:
f(notfreqHz), e.g.SineVoltage(V=.., f=..) - declare the dependency with the exact MSL version, e.g.
annotation(uses(Modelica(version="4.1.0")))
Run python3 "<scripts-dir>/wsm_run.py" --mode info to get the exact MSL
version. wsm_run.py also warns on stderr if it spots a 3.2 name in the model.
When a flatten fails with Element not found ... in Modelica..., the MSL
component path is wrong (a misremembered name, not a missing install). Resolve
the correct path with the search-modelica-docs skill — e.g. sine is
Modelica.Blocks.Sources.Sine (not Math.Sine), difference is Math.Feedback
(not Math.Subtract), and saturation is Nonlinear.Limiter (not
Nonlinear.Saturation). Do not grep or walk the System Modeler install tree
to hunt for the class.
Using non-MSL libraries (Hydraulic, and other installed libraries)
MSL is automatic (--msl). For any other library a model uses — Hydraulic, or
anything the user installed from the Library Store — the launcher can find it for you.
Two steps, no guessing at paths:
See what is installed (bundled with System Modeler, user-installed archives, and any custom folders configured in Model Center):
python3 "<scripts-dir>/wsm_run.py" --mode libraries # add --json for a machine-readable array; each row has name/version/source/packageTo get just one library's package path (e.g. for a manual
--load):--mode libraries --library Hydraulic(add--library-version 2.1to pin a version).Load it into a build by name — add
--load-library <Name>to a validate / simulate / diagnose run (repeatable; pin a version withName==Ver):python3 "<scripts-dir>/wsm_run.py" --mode validate \ --model "<path>/M.mo" --name M --load-library HydraulicThe launcher resolves the library (bundled → user-installed → Model-Center custom path, newest version wins) and
loadFiles it before the model. A library usually pulls in MSL, so keep MSL on (auto, or--msl yes). Override a lookup with$WSM_LIBRARY_<NAME>(e.g.WSM_LIBRARY_HYDRAULIC=/path/to/package.moe), or fall back to an explicit--load <path-to-package.mo|.moe>.
Files (system-modeler-ai-toolkit)
-
PlotAnnotate
-
figures.py 15.2 KB
Loading… -
inject.py 3.7 KB
Loading… -
main.py 9.1 KB
Loading… -
parser.py 1.1 KB
Loading… -
simvars.py 1.4 KB
Loading… -
suggest.py 1.8 KB
Loading… -
__init__.py 398 B
Loading…
-
-
SKILL.md 32.7 KB
--- name: annotate-modelica-plots description: "Add standardized Modelica result-plot annotations (Documentation(figures={Figure/Plot/Curve/Axis})) to a .mo model so simulation plots are stored in the model itself and reopen in Wolfram System Modeler. Use this skill whenever the user wants to store, embed, or save result plots in a model, define which variables to plot, add a figures annotation, or mark a time or a level on a stored plot with a labelled plot marker — a peak, a settling time, a threshold, a final value. Triggers on phrases like 'store the plots in the model', 'embed result plots', 'save these curves into the .mo', 'add a figures annotation', 'which variables should be plotted by default', 'mark the peak on the plot', 'add a marker at t = 2 s', 'show the settling time', 'draw a line at the limit', 'add measurements to the plot'." --- # Annotate Modelica Plots This skill writes the **spec-standard** result-plot annotation into a Modelica `.mo` file so a model carries its own simulation plots: ```modelica annotation(Documentation(figures = { Figure(identifier = "response", title = "Mass response", preferred = true, plots = { Plot(title = "Position and velocity", curves = {Curve(x = time, y = s, legend = "position"), Curve(x = time, y = v, legend = "velocity")}, x = Axis(label = "time"), y = Axis(label = "states", unit = ""))})})); ``` It is a **self-contained source transform**: Claude assembles a *figures spec* (JSON) — from the user's request, or from variables discovered by simulating — and the Python engine renders it to valid Modelica and splices it into the class annotation. The engine is pure Python (standard library only); WSMKernelX is used only afterwards as a validation gate. Wolfram System Modeler renders this standard annotation natively from the stored figure, picking up the `Plot.title`, `Axis.label`, and per-curve `legend`. No vendor-specific annotation is needed. It can also add System Modeler **plot markers** (`__Wolfram_markers`): labelled lines drawn on the stored plot. A vertical marker at a time makes the plot's Measurements panel list every curve's value at that time; a horizontal marker at a level lists every time a curve crosses it. See [step 3c](#3c-markers--mark-a-time-or-a-level-optional). It is **idempotent**: a class that already has `figures =` is skipped unless you pass `--force` (which strips the old `figures` assignment and regenerates). By default it prints a dry-run diff; nothing is written until `--write`. > **`--force` is destructive — ask the user first.** It deletes the class's existing `figures` > block before regenerating, so any hand-written or previously curated plot definitions there are > lost (a user may have tuned those by hand). Don't pass `--force` on a class that already carries > figures without first confirming with the user that discarding them is intended. Review the > dry-run diff (no `--write`) to see exactly what would be removed. ## The figures spec (JSON) Shaped after the spec records (MLS `annotations.tex` §figure-plot-properties). Only fields you set are emitted: ```json { "figures": [ { "title": "Mass response", "identifier": "response", "preferred": true, "caption": "Damped oscillation of %[position](variable:s).", "plots": [ { "identifier": "states", "title": "Position and velocity", "x": {"label": "time"}, "y": {"label": "states", "unit": "", "scale": "Linear"}, "curves": [ {"x": "time", "y": "s", "legend": "position"}, {"x": "time", "y": "v", "legend": "velocity"} ] } ], "markers": [ {"identifier": "first_min", "x": 1.0, "xUnit": "s", "label": "first minimum", "plots": ["states"], "labelPosition": {"yOffsetCanvas": 0.9, "verticalAlignment": "Top"}}, {"identifier": "rest", "y": 0.0, "yUnit": "m", "label": "rest position"} ] } ] } ``` Marker fields (a position is required, the rest is optional): - `x` **or** `y` — `x` is a vertical line at a position on the x axis, `y` a horizontal line at a level. Never both: System Modeler does not draw such a marker. On a time-based plot `x` is a time (`"xUnit": "s"`); on an X vs. Y plot it is a value of the x variable, in its unit (e.g. `"x": 0, "xUnit": "mm"`) — a time there lands at that value of the x variable instead. - `yUnit` — the unit of a `y` level. Always set it, preferably to the unit the plot's y axis shows; without it the number is read in the axis unit, whatever that is. - `label` — text drawn on the line. `%{var}` shows the variable's final value in its display unit. - `plots` — plot identifiers or 0-based indices that show the marker; default is every plot of the figure. Restrict a `y` marker to the plots whose y axis it belongs to. - `labelPosition` — where the label sits along the line, from 0 to 1: `yOffsetCanvas` for a vertical marker (0 = bottom), `xOffsetCanvas` for a horizontal one (0 = left). Plus `verticalAlignment` (`Top|Center|Bottom`, default `Bottom`) and `horizontalAlignment` (`Left|Center|Right`, default `Left`). - `yAxis` — `"right"` for a level on the right y axis; default `"left"`. - `identifier` — unique within the figure; defaults to `m1`, `m2`, ... Rules the engine enforces (from the spec): - `Curve.x`/`Curve.y` must be **result-references**: a scalar variable (`s`, `mass.v`), `time`, or `der(v[, n])` — *not* arbitrary expressions. A bad reference is a hard error. `x` defaults to `"time"`; set it to a variable for an X vs. Y plot (e.g. `{"x": "s", "y": "v"}` for a phase portrait). - `Figure.identifier` must be unique in the spec; `Plot.identifier` unique within its figure. - A marker has exactly one numeric position, a unique identifier within its figure, and `plots` entries naming existing plots. - Axis `scale` is `"Linear"` (default), `"Log"`, or `{"Log": 10}` to set the base. - `%{var}` variable replacements and `%[text](variable:ref)` caption links are passed through; the engine does not invent them. To target a specific class in a multi-model file, either pass `--class <Name>`, or use a mapping spec `{"Oscillator": {"figures": [...]}, "Plain": {"figures": [...]}}`. ## Running the annotator The annotator lives in the `PlotAnnotate/` package next to this file. Run it as a module **from this skill's directory** so the package is importable: ```bash cd "<this-skill-dir>" python3 -m PlotAnnotate.main --file "<path-to-Model.mo>" --analyze ``` Use `python` instead of `python3` on Windows if that's what's on PATH. Only `--file` (and `--spec`, `--vars-file`) must be absolute or correctly-relative paths. ## Cross-platform launcher (for simulate / validate steps) > The simulate/validate steps below call the shared `scripts/wsm_run.py` and > `scripts/plot_mat.py`. Read [the shared-conventions appendix at the end of this file](#appendix-shared-conventions-for-the-modelica-skills) > (launcher resolution, shell rules, temp dir, JSON-array output, MSL 4.x notes) > before those steps. In a normal install the launcher is `../scripts/wsm_run.py` > (`<scripts-dir>` is the shared `scripts/` folder); if that path doesn't exist, > see [Appendix → Locating the launcher](#locating-the-launcher). ## Workflow ### 1. Identify the model file and target class The user gives a `.mo` path. Pick a **concrete instantiable model** for any kernel step (`Package.Model`, not the package) — see [Appendix → Picking the model name](#picking-the-model-name). ### 2. Analyze — see classes and existing figure status ```bash python3 -m PlotAnnotate.main --file "<Model.mo>" --analyze ``` Lists every class, flagging `has Documentation` / `HAS figures`. Present this and confirm scope. ### 3. Choose what to plot Pick curves that reveal *emergent / non-obvious* behavior — a dynamic response, a comparison, a phase shift, a limit case. Skip tautological curves that just re-trace a known input signal (if you'd see the same shape by plotting the input alone, it teaches nothing). Curves default to `x = time`, but `Curve.x` can be any result variable, giving an **X vs. Y plot**. Reach for one when the relationship between two variables is the story: a phase portrait of an oscillator (limit cycles show as closed loops), a hysteresis loop, a transfer or force- displacement characteristic. Put an X vs. Y curve in its own `Plot` (not mixed with time-based curves — they'd share the x axis) and label both axes. **Mode A — user-specified.** The user already knows the curves. Build the spec JSON directly from their request and skip to step 4. **Mode B — simulate-and-suggest.** When the user doesn't name variables, discover them: ```bash # simulate to produce a .mat (and, beside it, a .sim init file with the same stem) python3 "<scripts-dir>/wsm_run.py" --mode simulate --model "<Model.mo>" --name "<Package.Model>" --timeout 180 # enumerate result variables (write working files next to the model, not into the skill dir) python3 "<scripts-dir>/plot_mat.py" "<temp-dir>/<result>.mat" --list > "<Model-dir>/vars.txt" # get a starting spec (filters time/der/aux; one plot, x=time). Pass the .sim so protected # variables are dropped — they are stored in the .mat but render blank in a stored figure. python3 -m PlotAnnotate.main --file "<Model.mo>" --vars-file "<Model-dir>/vars.txt" \ --sim-file "<temp-dir>/<result>.sim" --suggest --max-curves 8 > "<Model-dir>/figs.json" ``` `<result>.mat` is the file named by `simulation.resultFile` in `simulate.out.json`; the `.sim` file sits next to it with the same stem (swap the `.mat` extension for `.sim`). Passing `--sim-file` is what stops protected variables from being suggested — without it, a protected variable in the result is offered as a curve and then renders blank in System Modeler. The suggestion is a **starting point** — refine `figs.json`: drop parameters/noise, split into multiple `plots` by physical quantity, set titles/legends/axis units. Passing `--vars-file` to the `--annotate` step also warns when a curve references a variable absent from the result; passing `--sim-file` there additionally warns when a curve references a protected variable. ### 3b. Title, caption, and reference alignment Every figure should be self-identifying and self-explaining: - **Title** — name the quantity shown, not "Plot 1" (e.g. `"Refrigerant pressure"`). The title is how the user finds the plot in the model's figure list, so make it scannable. - **Caption** — set a one-line `caption` on *every* `Figure` saying what it shows and what to look for (e.g. "Pressure rises with the accumulation after the step"). It renders beneath the plot in System Modeler. Use `%[label](variable:ref)` to link a variable inside the caption. - **Default** — mark exactly one figure `preferred = true` so it opens by default. - **Reference alignment** — if the model implements a **published reference** (a paper, app note, textbook) and that reference numbers its figures, name the model's figures to match it (`"Fig. 6 - Stored refrigerant mass"`) and state the correspondence in the caption ("compare Fig. 6 of <citation>"). This makes a replication auditable at a glance — anyone can line the stored plot up against the source. When no reference is given, use your own clear, ordered scheme (e.g. `"Evaporator 1 - Outlet vapour quality"`). ### 3c. Markers — mark a time or a level (optional) Add markers when the user asks to mark, measure or label something on a plot, or when a caption makes a claim ("settles in 13 s") that a marker makes visible. Keep them few: two or three that support the caption beat a marker on every extremum. If the user gives the numbers ("a line at 3 bar", "mark t = 2.5 s"), write the markers into the spec directly. Otherwise simulate (as in Mode B) and let `mat_features.py` find the positions and add the markers to a figure of the spec. Each feature is `VAR:KIND[:ARG]`: | Feature | Marker | |---------|--------| | `s:max`, `s:min` | vertical line at the time of the extremum | | `s:at:2.5` | vertical line at t = 2.5 s | | `s:settle:0.02` | vertical line at the settling time: within 2 % of the step of its final value, or of its largest deviation from it when `s` returns to where it started; fails if `s` is still outside that band in the last 10 % of the run | | `s:cross:0.5` | horizontal line at the level 0.5, in the unit the marker is written in | | `s:final`, `s:initial` | horizontal line at the final / initial value | ```bash python3 "<scripts-dir>/mat_features.py" "<temp-dir>/<result>.mat" s:min s:settle:0.02 \ --spec "<Model-dir>/figs.json" --figure response --plots states ``` Horizontal lines are written in the unit the plot's y axis shows (the plot's `Axis.unit`, else the variable's `displayUnit`); pass `--unit bar` to choose it, which also sets the unit of a `cross` level. Run it once per group of plots that share a y axis. Without `--spec` it prints the markers as JSON; for a mapping spec, name the class with `--class`. Re-running a feature replaces its marker. Labels carry the measured value; the `final` label uses `%{var}`, so it stays correct after the model changes. ### 4. Preview — dry-run diff ```bash python3 -m PlotAnnotate.main --file "<Model.mo>" --class "<Model>" --spec "<Model-dir>/figs.json" --annotate ``` Shows the unified diff without writing. `--vars-file "<Model-dir>/vars.txt"` adds membership warnings, and `--sim-file "<temp-dir>/<result>.sim"` warns on any curve that references a protected variable. `--force` regenerates over an existing `figures` block. ### 5. Apply — write in place ```bash python3 -m PlotAnnotate.main --file "<Model.mo>" --class "<Model>" --spec "<Model-dir>/figs.json" --annotate --write ``` Re-running without `--force` is a no-op for already-annotated classes (idempotent). ### 6. Validate — confirm the model still flattens (validate-modelica gate) Annotations must not change the flatten result, and System Modeler must accept every part of the figures. `--figures` has the kernel parse them as System Modeler does when it opens the plots. ```bash python3 "<scripts-dir>/wsm_run.py" --mode validate --figures --model "<Model.mo>" --name "<Package.Model>" --timeout 90 ``` Parse `<temp-dir>/validate.out.json` (a JSON array — take `[0]`; field reference: [Appendix → Reading the JSON output](#reading-the-json-output)) and check `status.flatten == "Pass"`. If it passed before annotating but fails after, that's a bug in the annotation, not the user's model — report it. The launcher also prints a `figures :` line and exits non-zero, listing each part System Modeler would ignore (a malformed curve, an unknown attribute, a misspelled `MarkerPosition`); fix those in the spec and regenerate rather than editing the `figures` block by hand. Then remove the temp dir. ## Notes and edge cases - **Pick an instantiable model for the kernel steps**, not the package — use a nested model's full dotted name. See [Appendix → Picking the model name](#picking-the-model-name). - **`figures` is inherited.** A class's figures = its own plus those from base classes. Keep `Figure.identifier`s unique across that whole collection (the engine checks within one spec; it can't see base-class figures, so choose distinct identifiers when extending). - **Result-references only.** To plot a derived quantity, add a variable for it in the model and reference that — `Curve.y` cannot be an expression like `s + v`. - **No protected variables in curves.** System Modeler stores protected variables in the result `.mat` (so `plot_mat.py --list` shows them), but a stored figure resolves curves against the public result tree only — a curve on a protected variable renders **blank**, and the model still flattens, so the validate gate won't catch it. The `.sim` file beside the `.mat` marks them (`protected="true"`); pass it as `--sim-file` to `--suggest`/`--annotate` so they are dropped and flagged. If you must show a protected quantity, expose it through a public variable in the model. - **X vs. Y (parametric) curves are supported.** `Curve.x` defaults to `time`, but any result-reference works (`Curve(x = x, y = y)`), and System Modeler renders the variable-vs-variable curve natively. Same rules as `y`: a result-reference (no expressions), and a protected variable renders blank on either axis. Don't mix time-based and X-vs-Y curves in one `Plot` — all curves share the plot's x axis (the engine warns on this); use separate plots. Label both axes, since the default "time" x-label no longer applies. A vertical marker on an X vs. Y plot sits at a value of the x variable, not at a time, so restrict `mat_features.py`'s time features (`max`, `min`, `at`, `settle`) to time-based plots with `--plots` (it refuses otherwise). - **Marker positions are numbers.** A marker does not move when parameters change; after re-tuning, re-simulate, re-run `mat_features.py` and regenerate with `--force`. - **Units.** A non-empty `Axis.unit` must be compatible with the plotted variable's unit, or the model won't flatten; leave `unit = ""` to let the tool choose per-curve units. - **Idempotency / regen.** Default runs never duplicate a `figures` block; use `--force` to regenerate after editing the spec — but it discards the existing figures (hand-written included), so confirm with the user first (see the caution near the top). - **MSL dialect (this toolchain ships MSL 4.x).** Annotations don't affect flattening, but if the *model* uses 3.2 names it fails the gate for unrelated reasons — see [Appendix → MSL 4.x dialect](#msl-4x-dialect). --- ## Appendix: shared conventions for the Modelica skills > *Shared by every Modelica skill that drives WSMKernelX through the > bundled launcher; inlined here at release time. For the CLI/option > reference, environment variables (`WSM_HOME`, `WSM_VSDEVCMD`), > install discovery, and the analysis scripts, see > [`../scripts/README.md`](../scripts/README.md).* **These are conventions, not a workflow.** Knowing how to call the tools is not the same as knowing which to call, in what order, and how to tell a good answer from a plausible one — that lives in the skills, one per job. Invoke the one that owns the step you are on, **including when it is not the one you started from**: a job that begins in one skill routinely runs into something another one owns, and the whole toolkit is available the entire time. | What you run into | Skill | |---|---| | About to write or restructure a model or library — including one you decided to build yourself | `modelica-model-architecture` **first** | | A `.mo` you just wrote or edited; a structural error | `validate-modelica` | | You need results | `simulate-modelica` (`simulate-and-plot-modelica` to plot them too) | | A run that must go in real time, take input changes while it runs, or be driven from another program | `simulate-modelica-realtime` | | It validates but will not build; it runs far too slowly; it gives an answer you cannot account for; you need its states, equations or blocks | `diagnose-modelica` | | The launcher reports a `compiler failure` — an internal error, generated code that does not compile, a simulator internal error or a kernel crash | `minimize-modelica-bug` | | A Modelica language or MSL question you would otherwise answer from memory | `search-modelica-docs` | | Sweeps, limit checks, calibration, custom result analysis | `wolfram-language-modelica` | | No icons, or no diagram layout | `annotate-modelica-graphics` | | Plots that should live in the model and reopen with it | `annotate-modelica-plots` | | Interactive sliders in Simulation Center's Explore view | `annotate-control-panel` | | 3D MultiBody animation | `annotate-modelica-animation` | | A hydraulic circuit | `create-hydraulic-model` | ### Locating the launcher `<scripts-dir>` (used throughout the skills) is the shared `scripts/` folder. Some installs symlink the skill directories without it, so resolve it in this order and use the first that exists: 1. `$WSM_SKILLS_SCRIPTS` (bash) or `$env:WSM_SKILLS_SCRIPTS` (PowerShell), if set. 2. `../scripts` relative to the skill directory — in a normal install `../scripts/wsm_run.py` already exists, so use that path directly; **do not run a shell probe to "resolve" it.** 3. The folder you cloned or unzipped the skills from, e.g. `.../system-modeler-ai-toolkit/scripts`. 4. Last resort, search the home directory: - PowerShell: `Get-ChildItem $HOME -Recurse -Filter wsm_run.py -ErrorAction SilentlyContinue | Select-Object -First 1` - bash/zsh: `find ~ -name wsm_run.py -path '*scripts*' 2>/dev/null | head -1` If only #4 finds it, the install is missing the `scripts/` link — tell the user to run `install.sh` (or `install.ps1`) from the repo, which links `scripts/` too. ### Shell and Python **On Windows, use PowerShell.** The Git-Bash/cygwin layer may be broken (even `ls`/`find` can be absent, giving a misleading "exit 127 / command not found"). Run `wsm_run.py` with `python` (not `python3`); those calls are single-line and shell-agnostic. For cleanup use `Remove-Item -Recurse -Force`, not `rm -rf`. On macOS/Linux any POSIX shell is fine and `python3` is the usual name. **For your own analysis, borrow the scripts' interpreter.** Whatever `python3` you get is unlikely to have numpy or scipy, and installing into it is both rude and often blocked. The analysis scripts run under a managed virtualenv with numpy, scipy, matplotlib and DyMat; `python3 <scripts-dir>/bootstrap_env.py` makes sure they are installed there and prints its interpreter path. Use that interpreter for ad-hoc post-processing rather than discovering package by package what the system one lacks. ### Line endings in .mo files Modelica models are written on Windows, macOS and Linux alike, so a `.mo` file may use CRLF or LF. **Neither is the "right" one.** Match whatever the file already has, and never leave a file with a mix of both — a mixed file shows up as a whole-file diff the moment anything rewrites it, burying the real change. When you edit a `.mo` yourself with the Write/Edit tools (rather than through one of the annotator scripts), those tools write back exactly the text you give them, so an edit in the other style silently mixes the file. Check before, and check again after: ```bash python3 "<scripts-dir>/mo_edit.py" --eol "<Model.mo>" ``` It prints `LF`, `CRLF`, `MIXED (crlf=N lf=M)` or `NONE`, and exits non-zero on `MIXED`. If an edit did change the endings, put them back — this rewrites the whole file to one ending, so it also repairs a mixed one: ```bash python3 "<scripts-dir>/mo_edit.py" --set-eol auto "<Model.mo>" # or: lf, or crlf ``` **A mixed file follows its library, not itself.** If the file you are editing is mixed while the rest of the library is consistent, do not settle it on whichever ending dominates *inside* that file — the mixing is damage, so the file is not evidence about itself, and its majority leaves you with the one odd file out. Use the library's ending. `auto` does this for you, and reports which rule it applied. Creating a new `.mo`: same rule — match the sibling `.mo` files in the same directory or library (`--eol` accepts several paths at once), so one library does not end up half CRLF and half LF. Use LF only when there is nothing to match. The annotator scripts' `--write` paths already preserve the file's endings and warn about a mixed input, so no manual step is needed around those. ### Let the launcher own .mos/.bat and paths Do **not** hand-write `.mos` scripts, `.bat` files, or hardcode install/compiler paths. The bundled `scripts/wsm_run.py` handles every OS difference — it finds the System Modeler install and kernel binary (macOS / Windows / Linux), finds and loads the right MSL files, generates the `.mos`, and runs the kernel with a working compiler environment per platform (system clang/gcc on macOS/Linux; the Visual Studio dev environment via `VsDevCmd.bat` on Windows). See [`../scripts/README.md`](../scripts/README.md) for `WSM_HOME`, the Windows compiler prerequisites, and the full option table. ### When the install or compiler isn't found The launcher searches each OS's standard install locations. If it prints `ERROR: Could not locate a Wolfram System Modeler installation`, the install is in a non-standard place — ask the user for it and re-run with `--wsm-home "<path>"` (or have them set `WSM_HOME`). Building and simulating also need a C++ toolchain: - **Windows**: Visual Studio Build Tools. The launcher locates `VsDevCmd.bat` itself; if it reports the compiler environment is missing, pass `--vsdevcmd "<path-to-VsDevCmd.bat>"` (or set `WSM_VSDEVCMD`) and make sure Build Tools are installed. - **macOS**: the Xcode command-line tools (`xcode-select --install`). - **Linux**: gcc/g++. Run `python3 "<scripts-dir>/wsm_run.py" --mode info` to see what the launcher discovered. ### Checking the setup When the user asks whether the machine is ready for these skills, run `python3 <scripts-dir>/wsm_run.py --mode info` and report what it prints: the System Modeler installation it found and, on Windows, the compiler environment. If `InstallationGuide.md` sits next to the `scripts/` folder, as it does when the skills are installed as a plugin, it lists what each skill needs: follow its Steps 2, 4 and 5, and do not run the installer. ### Temporary directories The launcher works in a `_wsm_<mode>_temp/` directory (`_wsm_validate_temp/`, `_wsm_simulate_temp/`, `_wsm_diagnose_temp/`) and leaves its outputs there. It sits next to a single `.mo` file, or next to the top folder of a directory-form library, never inside the library. The launcher prints its path as `temp dir :`; `<temp-dir>` in the skills means that path. Tell the user, e.g.: "Working in temporary directory `_wsm_<mode>_temp/`. This will be deleted afterwards." Pass `--tempdir` to reuse one directory across models in a session. Clean up by removing the whole directory — use the user's shell: ```bash rm -rf "<temp-dir>" # macOS / Linux # PowerShell: Remove-Item -Recurse -Force "<temp-dir>" ``` ### Picking the model name - The user may provide a path to a `.mo` file, or you may already be working with one in context. - Extract the **model name**: the identifier after `model` on the first non-comment line, e.g. `model FooBar` → `FooBar`. The filename does not always match the model name — parse the actual `model`/`package` declaration. - For packages or nested models, use the **top-level** model name. - **Pick an instantiable model, not a package**, for any kernel call. A `package` cannot be validated or simulated ("Invalid instantiation … is a package") — use a nested model's full dotted name, e.g. `Package.Model`. - Pass an **absolute path** to `--model` (relative paths break as the working directory shifts between calls). - **A class that is already in a loaded library needs no `--model` at all** — give just the full dotted `--name` and the launcher takes it from MSL (or from a `--load-library` library). Use this for MSL examples rather than writing a wrapper model that extends one: ```bash python3 "<scripts-dir>/wsm_run.py" --mode diagnose \ --name Modelica.Mechanics.MultiBody.Examples.Loops.EngineV6 ``` The temp dir then goes in the current directory. `--model` is still required for a class in the user's own file. ### Directory-form (multi-file) libraries A directory-form library stores one class per file with a `package.mo` at each level. You **cannot** validate such a class by handing the launcher only its own `.mo` file — the class's `within Lib;` clause needs the whole package loaded, and loading the single file alone fails with `Internal error: ... expandLibNode: Unknown library: Lib`. Instead point `--model` at the **library folder** (or its top `package.mo`, or any class file inside it) and pass the **full dotted class name** via `--name`: ```bash python3 "<scripts-dir>/wsm_run.py" --mode validate \ --model "/abs/path/InvertedPendulum" \ --name InvertedPendulum.Controller ``` The launcher resolves any of those forms up to the library's root `package.mo` and loads the entire package (following `package.order`) before instantiating `--name`. It prints a `NOTE:` telling you which `package.mo` it loaded. Do **not** try to work around the unknown-library error by `--load`-ing individual files. ### Reading the JSON output The kernel writes `<mode>.out.json` into the temp dir. **It is a JSON *array* — take the first element**, then read: - **`status.flatten`**: `"Pass"` / `"Fail"` (the primary result for `validate`). - **`status.build`**: `"Pass"` / `"Fail"` — C++ compilation/linking (`simulate`). - **`status.result`**: simulation result status (`simulate`). - **`messages.errors`** / **`messages.warnings`** / **`messages.notifications`**: arrays (empty if none). - **`flat_model`** (`validate`) / **`simulation.resultFile`** (`simulate`): the flattened class / path to the `.mat`. See [`../scripts/README.md`](../scripts/README.md) (`wsm_run.py` section) for the full field reference. ### Checking graphic annotations A plain run does not evaluate the graphic annotations: `Icon`, `Diagram` and `Placement` are carried along untouched, so an error inside one cannot fail the run. Add `--graphics` to have them evaluated together with the model: ```bash python3 "<scripts-dir>/wsm_run.py" --mode validate --graphics \ --model "<Model.mo>" --name "<Package>.<ModelName>" --timeout 90 ``` Errors then arrive through the usual `status.flatten` and `messages.errors`: a variable or component path that does not resolve, a misspelled shape (`Rectangel`) or field (`extend`), an array subscript out of bounds. This mode needs no C++ compiler, so it is the gate to run after editing annotations. The compiling modes (`--mode simulate`, `--mode diagnose`) additionally generate the model's diagram view, which evaluates the animated (`DynamicSelect`) expressions themselves. The launcher prints a `graphics :` line naming the generated view; if it was not generated it says so and exits non-zero, meaning an animated field could not be evaluated. It also exits non-zero, listing them, when an animated value falls back to its static value — typically an expression using a function the diagram does not support. Nothing else reports either. Evaluating the annotations is extra work for the frontend, so pass `--graphics` when the annotations are what you changed or are checking, not by default. Not every System Modeler version supports `--graphics`. On one that does not, the launcher drops it with a `NOTE:` and runs without it, so the graphic annotations are **not** checked; say so rather than reporting them as valid. ### MSL 4.x dialect This toolchain ships **MSL 4.x**. When authoring models, use the 4.x names — the 3.2 names flatten with confusing "not found" errors: - units: `Modelica.Units.SI.*` (not `Modelica.SIunits.*`) - source frequency parameter: `f` (not `freqHz`), e.g. `SineVoltage(V=.., f=..)` - declare the dependency with the exact MSL version, e.g. `annotation(uses(Modelica(version="4.1.0")))` Run `python3 "<scripts-dir>/wsm_run.py" --mode info` to get the exact MSL version. `wsm_run.py` also warns on stderr if it spots a 3.2 name in the model. **When a flatten fails with `Element not found ... in Modelica...`**, the MSL component path is wrong (a misremembered name, not a missing install). Resolve the correct path with the **search-modelica-docs** skill — e.g. sine is `Modelica.Blocks.Sources.Sine` (not `Math.Sine`), difference is `Math.Feedback` (not `Math.Subtract`), and saturation is `Nonlinear.Limiter` (not `Nonlinear.Saturation`). **Do not** grep or walk the System Modeler install tree to hunt for the class. ### Using non-MSL libraries (Hydraulic, and other installed libraries) MSL is automatic (`--msl`). For **any other** library a model uses — Hydraulic, or anything the user installed from the Library Store — the launcher can find it for you. Two steps, no guessing at paths: 1. **See what is installed** (bundled with System Modeler, user-installed archives, and any custom folders configured in Model Center): ```bash python3 "<scripts-dir>/wsm_run.py" --mode libraries # add --json for a machine-readable array; each row has name/version/source/package ``` To get just one library's package path (e.g. for a manual `--load`): `--mode libraries --library Hydraulic` (add `--library-version 2.1` to pin a version). 2. **Load it into a build** by name — add `--load-library <Name>` to a validate / simulate / diagnose run (repeatable; pin a version with `Name==Ver`): ```bash python3 "<scripts-dir>/wsm_run.py" --mode validate \ --model "<path>/M.mo" --name M --load-library Hydraulic ``` The launcher resolves the library (bundled → user-installed → Model-Center custom path, newest version wins) and `loadFile`s it before the model. A library usually pulls in MSL, so keep MSL on (auto, or `--msl yes`). Override a lookup with `$WSM_LIBRARY_<NAME>` (e.g. `WSM_LIBRARY_HYDRAULIC=/path/to/package.moe`), or fall back to an explicit `--load <path-to-package.mo|.moe>`.
Comments (0)
Sign in to join the conversation.
Reviews (0)
No reviews yet.
No comments yet.