Meteor Mcp

Meteor scatter MCP server: shower timing, radiant windows, live flux and fireballs

LLM Mart 0 views 1 listing impressions
Transport
Not stated
Package
—
Registry id
io.github.qso-graph/meteor-mcp

No install snippet on purpose. A working MCP config is a command, its arguments and an environment block — the last two are where API keys live, so this catalogue never stores them and cannot publish them. Follow the link above for the authors' own instructions.

Meteor scatter planning for amateur radio: can these two stations work each other on this shower, and when.

That is the whole shape of it. Meteor scatter is a point-to-point mode, so a radiant elevation on its own tells an operator nothing they can act on — the question is always about a path between two stations.

Part of the qso-graph project.

What decides a meteor-scatter contact

Three things, and radiant elevation is only one of them.

1. Path length. Trails burn at about 85–120 km, so a single-hop reflection off something that low works from roughly 400 km to about 2300 km. Shorter and the reflection point would have to be nearly overhead, where there is very little qualifying sky; longer and it sits below both horizons. 800–2000 km is where the geometry is best, and it is what hams actually run.

2. Radiant elevation at the path midpoint — not at either station. The reflection happens near the middle, so that is the sky that matters. Below the horizon there are no trails to reflect from. Very high is also poor, because trails then run down the path rather than across it.

3. The angle between the radiant and the path. This is the one usually left out, and it is the one that decides whether a reflection is geometrically possible at all. A trail reflects specularly only where it is tangent to the ellipsoid with both stations at its foci. Trails running along the path can never be tangent to it; trails running across it can. So a radiant broadside to the path is good and a radiant up- or down-path is poor — at the very same elevation.

All three are reported, and the verdict says which one decided it.

Why there is no score out of a hundred

Because the physics above is a tangency condition, and what a station actually hears also depends on its power, its antenna and the sporadic background. A figure like "73" would imply a precision none of that supports. So the answer is no / marginal / good / best, each with the reason beside it.

Where the numbers come from

Shower radiants, numbers and names are the IAU Meteor Data Center's — the body that names and numbers meteor showers. The package carries the facts read from the MDC's Established showers file with its URL and SHA-256 recorded, so the exact edition served is identifiable. The MDC is maintained on an unpaid voluntary basis and asks to be cited; its requested references are returned by meteor_source_info, printed in NOTICE, and travel inside every answer that uses a radiant.

The MDC lists several published solutions per shower, each from a different study. All of them are kept and none is blended — the average of two published radiants is a third that nobody published and no paper stands behind. Tools return the first-listed solution, labelled, and meteor_shower_info gives them all.

Peaks are stored as solar longitude, not as dates, because that is how the catalogue publishes them and it is the right way round: solar longitude names the same point in the stream every year, while a date drifts. This server converts it to the date it falls on in the year you ask about.

Two tools read the network, because only those two report what is happening right now:

Source Used for Licence
Global Meteor Network Confirmed meteor counts today, by shower CC BY 4.0 — attribution is a licence condition, and is returned in the answer
NASA CNEOS Recent fireballs US government work

Everything else is computed locally and needs no network at all.

Your own end comes from your station profile

meteor_window needs both ends of the path, but you should not have to retype your own. Your end is optional, and a host that knows the operator's station supplies it — in QG Desktop that is the Station component.

From the project's README.